EM TEST NetWave Series (3-Phase) AC/DC Power Sources

Description

EM TEST NetWave Series (3-Phase) AC/DC Power Sources offer powerful waveform generation capabilities for various test applications in the EMC area and for avionics testing. Based on a Dual-Processor technology, with an integrated high-performance PC, a digital signal processor (DSP) and equipped with a hard disk, the NetWave Series is capable to generate and record waveforms in real-time.

According to standard requirements a pure sinusoidal voltage is needed for harmonics and flicker measurements. The output voltage of the NetWave Series is therefore guaranteed to have a very low distortion (THD) of less than 0.1% regardless of the load. No matter whether waveforms are programmed of segments or of single points (normally resulting in MBs of data) the NetWave masters it all.

Interfaces like GPIB and Ethernet are common features with the NetWave Series.

 

MODEL OVERVIEW

NetWave 20.x 22,5 kVA AC / 27 kW DC support with wheels
NetWave 30.x 30 kVA AC / 36 kW DC, support with wheels
NetWave 67.x 67 kVA AC / 72 kW DC, support with wheels optional
NetWave 90.x 90 kVA AC / 110 kW DC, stationary placement
NetWave 108.x 108 kVA AC / 150 kW DC, stationary placement

Features

  • Wide Power Bandwidth; DC – 5 kHz
  • Output Power up to 270 kVA AC / 324 kW DC
  • Output up to 3*690 VAC (p-p), +/-1120 VDC
  • High Inrush Current Capability
  • Power-recovery up to nominal power (optional)
  • Built-in Arbitrary Waveform Generator
  • Standard Test Routines for IEC/EN requirements as well as for Aircraft and MIL-STD testing
  • Multiple Interfaces
Download Data Sheet
Print
Email

Specifications

GENERAL DATA (ALL MODELS)
SPECIFICATIONS
Output frequency DC – 5,000 Hz
Frequency accuracy 100 ppm
Output connectors Safety lab connectors

CEE type 32 A (only for NetWave 20.x and NetWave 30.x)

Interfaces GPIB

Ethernet

RS 232 (input from DPA analyser)

Frame bus (internal system bus)

Phase accuracy Resolution 1°
Output noise < 50 V: 110 mV rms

> 50 V: 320 mV rms

Slew Rate 8V/μs
REGULATION
Voltage sense Internal or external, 4 wires
Distortion (THD) Less than 0. 5%, @50/60 Hz
Output voltage Stability Better than 0.1 %
Output voltage Accuracy Better than 0.5 %
Max. compensable drop on wires 5 % of V nominal
Current limiter 5 A to Imax

Stop / Continuous (behavior)

Protection Over current

Over voltage

Over temperature

Low voltage

TRIGGER AND DUT MONITORING
Trigger 2 inputs, 2 outputs
DUT monitors 2 inputs, configurable