EM TEST OCS 500N6-series Oscillatory Wave Simulator
Description
EM TEST OCS 500N6-series Simulator for Ringwave and Damped Oscillatory Waves
The Ringwave is a non-repetitive damped oscillatory transient occurring in low-voltage power, control and signal lines supplied by public and non-public networks. Damped Oscillatory Waves are repetitive transients mainly occurring in power, control and signal cables installed in high voltage and medium voltage stations.
EM TEST OCS 500N6-series is a compact standalone simulator with test capabilities for ringwave up to 6kV as per IEC/EN 61000-4-12 and the damped oscillatory waves at 100 kHz and 1 MHz up to 3 kV as per IEC/EN 61000-4-18. The Damped Oscillatory Waves not only comply with IEC/EN 61000-4-18 requirements but also correspond with the requirements to test protective relays and relay systems as per ANSI/IEEE C37.90.
The OCS 500N6-series offers the Quick Start test routine where parameters can be changed on-line during the test to evaluate the susceptibility level of an individual DUT.
MODEL OVERVIEW
OCS 500N6.5 With built-in CDN 250 V / 16 A
OCS 500N6.6 With built-in CDN 250 V / 32 A
OCS 500N6.7 With built-in CDN 3×440 V / 16 A
OCS 500N6.8 With built-in CDN 3×440 V / 32 A
OCS 500N6.20 With built-in CDN 3×690 V / 100 A
Features
- Standalone test generator
- Includes Ringwave up to 6 kV
- Includes Damped Oscillator Waves up to 3 kV
- Built-in CDN, single phase or three-phase up to 100 A
- Front panel operation
- Standard Test routines
- USB and GPIB interfaces
Specifications
MODEL OVERVIEW WITH BUILT IN CDN | |
OCS 500N6.5 | 250 V / 16 A |
OCS 500N6.6 | 250 V / 32 A |
OCS 500N6.7 | 3×440 V / 16 A |
OCS 500N6.8 | 3×440 V / 32 A |
OCS 500N6.20 | 3×690 V / 100 A |
MODELS FOR RCCB TESTING | |
OCS 500N6.17 | 3×440 V / 32 A, calibrated according to IEC 61008-1 and IEC 61009-1 |
RINGWAVE AS PER IEC/EN 61000-4-12 AND ANSI/IEEE C62.41 | |
Voltage (o.c.) | 250V – 6,000V ± 10% |
Rise time | 0.5us ± 30% |
Oscillation frequency | 100kHz ± 10% |
Decaying | Ratio of peak 2 to peak 1: 0.4 – 1.1
Ratio of peak 3 to peak 2: 0.4 – 0.8 Ratio of peak 4 to peak 3: 0.4 – 0.8 |
Source impedance | 12ohm and 30ohm ± 20% |
Peak current (s.c.) | Max. 500A @ 12ohm or
Max. 200A @ 30ohm internally |
Rise time | 0.2us to 1.0us |
Oscillation frequency | 100kHz ± 10% |
Polarity | Positive, negative |
Repetition rate | 1/min or faster |
SLOW DAMPED OSCILLATORY WAVES AS PER IEC/EN 61000-4-18 | |
Voltage (o.c.) at HV output | 250V – 3,000V ± 10% |
Voltage (o.c) at line output | 250V – 2,500V ± 10% |
Rise time | 75ns ± 20% |
Oscillation frequency | 100kHz and 1MHz ± 10% |
Decaying | Peak 5 to be > 50% of peak 1 value
Peak 10 to be < 50% of peak 1 value |
Source impedance | 200ohm ± 20% |
Polarity | Positive, negative |
Repetition rate | Max. 50/s for 100kHz and Max. 500/s for 1MHz |
Burst duration | At least 2s |
INTERFACE | |
Serial interface | USB |
Parallel interface | IEEE 488, addresses 1 – 30 |
GENERAL DATA | |
Dimensions, weight | 19”/6HU, approx. 28kg (1-phase)
19”/6HU, approx. 33kg (3-phase) |
OCS 500N6.20 | 19”/25HU, approx. 210kg
550mm x 800mm x 1320mm |
Supply voltage | 115/230V +10/-15% |
Fuses | 2 x T 2AT (230V); 2 x T4 AT (115V) |