EM TEST VCS 500N10.2 Combination Wave Simulator
Description
EM TEST VCS 500N10.2 Combination Wave Simulator generates surge voltages up to 10kV and surge currents up to 5kVA as it is required for components testing (e.g. overvoltage protection for telecommunication devices) as per IEC/EN 61000-4-5.
To apply the surge pulse to power supply lines an external coupling/decoupling network either single phase or three-phase can be connected. The coupling modes and the source impedance are set automatically controlled by the VCS 500N10.2.
MODEL SERIES OVERVIEW
VCS 500N10-series Combination Wave Simulator; Surge pulses up to 10kV/5kVA
Features
- Surge pulses up to 10kV/5kVA
- Single phase or three-phase coupler up to 100A (external options)
- Fail inputs
- Warning lamp control
- Emergency interlock
- Standard test routines
- USB (optical link) and GPIB interface
Download Data Sheet
Print
Email
Specifications
TECHNICAL DETAILS | |
COMBINATION WAVE 1.2/50US – 8/20US | |
Voltage (o.c.) | 500V – 10,000V ± 10% |
Pulse front time | 1.2μs ± 30% |
Pulse time to half value | 50μs ± 20% |
Current (s.c.) | Max. 5,000A ± 10% |
Pulse front time | 8μs ± 20% |
Pulse time to half value | 20μs ± 20% |
Polarity | Positive/negative/alternating |
Event counter | 1 – 30,000 or endless |
TRIGGER | |
Trigger of events | Automatic, manual, external |
CRO trigger | 5V trigger signal for oscilloscope |
Synchronization | 0° – 360°, resolution 1° |
Repetition rate | 6s – 999s, depending on the voltage |
OUTPUT | |
Direct | 2 outputs via HV connectors;
– Zi = 2ohm – for external coupling networks |
VCS 500N10.2 | 10kV Surge Generator
1.2/50us – 8/20us; IEC coupling; CDN external; AC 690 V(p-p); 9HU; Rack required; used with CNV 503S19 or CNV 503S19.1 |
INTERFACE | |
Optical interface | Opto link, 3m cable
USB A connector |
Parallel serial interface | IEEE 488, addresses 1 – 30 |
CN interface | To control external coupling matrix |
SAFETY | |
Safety circuit | Control input (24Vdc) |
Warning lamp | Floating output contact |
GENERAL DATA | |
Dimensions – Weight | 19″/6HU, approx. 35kg |
Supply voltage | 115/230V +10/-15% |
Fuses | 2x T 2AT (230V) or 2X T 4AT (115V) |