EM TEST VCS 500N8-series Combination Wave Simulator

Description

Surge pulses occur due to direct or indirect lightning strokes to an external (outdoor) circuit. This leads to currents or electromagnetic fields causing high voltage or current transients. Another source for surge pulses are switching transients originating from switching disturbances and systems faults.

Due to the characteristic of the phenomenon nearly every electrical and electronical device may suffer from such lightning events which justifies the necessity of surge tests being widely performed. Surge voltage can reach several thousands of volts and surge current is seen to reach several thousands of amps.

Although generating voltages as high as 8kV the VCS 500N8-series offer an integrated coupling/decoupling network either single phase or three-phase with a nominal current of 16A per phase. In case higher current is required its capability can be extended by an external CDN to achieve nominal currents of 100A and more per phase.

 

MODEL OVERVIEW

VCS 500N8 8kV Surge Generator w/o. built-in CDN; an external CDN is required
VCS 500N8.1 8kV Surge Generator with built-in 1ph CDN 250V / 16A
VCS 500N8.2 8kV Surge Generator with built-in 3ph CDN 3*440V / 16A
VCS 500N8.3 8kV Surge Generator with built-in 3-phase CDN 3*690V (L-L) / 32A
VCS 500N8.5 8kV Surge Generator with built-in 3-phase CDN 3*440V (L-L) / 32A

Features

  • Surge voltage up to 8kV
  • Surge current up to 4kA
  • Voltage/current monitors
  • Built-in CDN 1-phase or 3-phase up to 3 x 690V and 32A
  • Interlock
  • Warning lamp control
  • Manual operation
  • USB (optical link) and GPIB interface
Download Data Sheet
Print
Email

Specifications

TECHNICAL DETAILS
COMBINATION WAVE 1.2/50US – 8/20US
Voltage (o.c.) 250V – 8,000V ± 10%
Front time 1.2μs ± 30%
Time to half value 50μs ± 20%
Current (s.c.) Max. 4,000A ± 10%
Front time 8μs ± 20%
Time to half value 20μs ± 20%
Polarity Positive/negative/alternating
Event counter 1 – 30,000 or endless
TRIGGER
Trigger of events Automatic, manual, external
CRO trigger 5V trigger signal for oscilloscope
Synchronization 0° – 360°, resolution 1°
Repetition rate 3s – 999s, depending on the voltage
OUTPUT
Direct Via HV connectors for external coupling networks (Zi = 2ohm with optional adapter IMN 2)
VCS 500N8.1 Built-in single-phase coupler

AC: 250V/16A; 50/60Hz

DC: 250V/10A

VCS 500N8.2 Built-in 3-phase coupler 3 x 440VAC / 16A; 50/60Hz

DC: 250V/10A

VCS 500N8.3 Built-in 3-phase coupler 3 x 440VAC / 32A; 50/60Hz

DC: 250V/20A

VCS 500N8.5 Built-in 3-phase coupler 3 x 690VAC / 32A; 50/60Hz

DC: 400V/20A

Coupling mode Line to line with 2ohm Line(s) to PE with 12ohm
INTERFACE
Serial interface USB
Parallel serial interface IEEE 488, addresses 1 – 30
SAFETY
Safety circuit Control input (24Vdc)
Warning lamp Floating output contact
GENERAL DATA
Dimensions – Weight
VCS 500N8 19″/6HU, approx. 25kg
VCS 500N8.1 19″/6HU, approx. 28kg
VCS 500N8.2 19″/6HU, approx. 35kg
VCS 500N8.3 19″/9HU, approx. 55kg
VCS 500N8.5 19″/9HU, approx. 52kg
Supply voltage 115/230V +10/-15%
Fuses 2x2AT (230V) or 2x4AT (115V)