EM TEST VDS 200N50 Voltage Drop Simulator

Description

EM TEST VDS 200N50 Voltage Drop Simulator is used to simulate various battery supply waveforms recommended by international standards and by car manufacturer requirements.

The VDS 200N50 serves as powerful DC voltage supply for the DUT during the test with automotive transients. The VDS 200N50 offers the QuickStart with parameters being adjustable during test to evaluate the susceptibility level of a DUT. Pulse 4 and 2b as per ISO 7637-2.

The VDS 200N50 has an integrated DC amplifier with a frequency range up to 50kHz. It generates dips and drops, short interruptions and voltage variations representing various phenomena being measured on a wiring harness.

EM TEST VDS 200N50 is best to simulate battery supply waveforms.

 

MODEL SERIES OVERVIEW

VDS 200N-series Voltage Drop Simulator – Battery Supply Simulation and DC Voltage Source

Features

  • Voltage up to 60V
  • Current up to 200A (peak up to 1,000A)
  • Bipolar-amplifier models available
  • Low output impedance
  • Powerful DC voltage source
  • Pulses 4 and 2b (ISO 7637-2/ISO 16750-2)
  • Pre-programmed test routines to simulate various supply waveforms
  • Input for external signal generator to produce most complex waveforms
  • Software for Windows Vista & Windows 7
  • USB and GPIB interfaces
Download Data Sheet
Print
Email

Specifications

COMMON DATA (ALL MODELS)
GENERAL
Source impedance Zi = <10mohm
Voltage deviation <1V with resistive load (including inrush current) recovering 63% of its maximum excursion within 100us
Ripple voltage Ur <0.2Vp-p, frequency min. 400Hz
Sinusoidal signal capability vs. Frequency *) Vpp max. 16V up to 20kHz

Vpp max. 10V up to 30kHz

Vpp max. 6V up to 50kHz

*) Vpp max. 3V up to 100kHz via Analog In, controlled by

AutoWave/AMP 200Nx only

Fuses Depending on VDS 200N model
OUTPUT
DUT Supply +/- Safety laboratory or high current connectors
Ext. Trigger 5-15V TTL; BNC connector
CRO Trigger 5V TTL – signal for oscilloscope
TEST ROUTINES FOR ARBITRARY WAVES
DC source Max. 60V; current depending on VDS 200N model
Functions Sine Wave Sweep

Sine Wave (Cranking)

Clipped Load Dump

Jump Start

Extern

GM 9105P Pulse 4

Drop and Jump pulse

Standard Test routines ISO 7637, Pulses 2b and 4

ISO 16750-2

JASO Test 1

Service Service, Setup, Self-test
INTERFACE
Serial interface USB
Parallel interface IEEE 488, addresses 1 – 30
Remote control To connect an external signal generator (10kohm): 0-10V / 0-50kHz Max.

0.5V(p-p) / 0-100kHz