EM TEST VDS 200Q50 Voltage Drop Simulator

Description

EM TEST VDS 200Q50 Voltage Drop Simulator is used to simulate various battery supply waveforms recommended by ISO and Automotive OEM standards.

The VDS 200Q50 simulator serves as a powerful DC voltage supply for the DUT during tests with automotive transients. The VDS 200Q50 can handle all three supply voltage categories (12 V, 24 V, and 42 V). The current capability ranges up to 100A (depending on the model and your application).

 

MODEL SERIES OVERVIEW

VDS 200Q-series 4-Quadrant Voltage Drop Simulator – Battery Simulator and DC Voltage Source

Features

  • Voltage up to 60 V, 2 ranges
  • Expandable to 77 V
  • Current up to 200 A (600 A peak)
  • Four quadrant operations
  • Fast step response time
  • Low output impedance
  • High Bandwidth
  • Temperature-controlled air cooling
  • Pre-programmed test routines to simulate various supply waveforms
  • Input for external signal generator to produce most complex waveforms
  • Software for Windows Vista & Windows 7
  • USB and GPIB interfaces
Download Data Sheet
Print
Email

Specifications

VDS 200Q50
Output Range -15 V – +30 V / +60 V
Output current 0 A – 50 A, continuous
Peak current 150 A for 200 ms
Bandwidth DC – 150 kHz full signal
Supply Voltage 3-phase 200/400 V ±10%, L1, L2, L3, PE
Dimensions 19″/25 HU
Weight 270 kg
COMMON DATA (ALL MODELS)
GENERAL
Source impedance Zi = <10 mohm
Operation 4 – quadrant, bipolar operation
Current limiter (not available for VDS 200Q10) 3x Imax: allows an inrush current of three times nominal current for 200 ms before the current limiter starts 3x ictrl: allows an inrush current of three times the programmed current for 200 ms before the current limiter starts Peak OFF: no inrush current above the set current value
Compensation STD: DC – 40 kHz

HF: DC – >=150 kHz

CAP: DC – 3kHz

Recovery >90% of excursion within 25 us
Output rise time typ. <10 us, <3 us (high freq.)
Ripple voltage Ur <10 mVp-p, frequency min. 400 Hz
Control Analog In
Cooling temperature-controlled air cooling
Protection Thermal-Magnetic Circuit Breakers Depending on VDS 200Q model
TRIGGER
Automatic Automatic release of the events
Manual Manual release of a single pulse
External External release of a single pulse
OUTPUT
DUT Supply +/- Safety laboratory or high current connectors
Ext. trigger 5-15 V TTL, BNC connector
CRO Trigger 5 V TTL-signal for oscilloscope
INTERFACE
Interfaces USB

Ethernet (for optional AutoWave)

IEEE 488, addresses 1 – 30

Remote control To connect an external signal generator (10 kohm): -10 V – +10 V / 0 – 150 kHz (180 kHz for VDS 200Q10)