ETS-Lindgren 3850-2 LISN 9 kHz - 100 MHz
Description
ETS-Lindgren Line Impedance Stabilization Networks (LISNs) are multi-line low pass filter networks used for conducted emissions measurement.
LISNs isolate an electrically powered EUT from the external power source, stabilize line impedance (for repeatable measurements), and provide a 50-ohm RF connection to measure EMI voltage generated by the EUT. When line currents drawn by the EUT are too great for a LISN, Model 3701 Line Probe can be used for EMI voltage measurements.
Features
- Insulated Plugs for Safer Power Connections
- Coils Matched for Application
- Individually Calibrated
- One Piece, Multi-Line Design for Convenience
Specifications
Electrical Specifications |
|
Frequency Minimum |
9 kHz |
Frequency Maximum |
100 MHz |
Maximum Current |
50 A |
Maximum Voltage |
220 VAC Line to Ground |
Power Out Connector |
Superior ® Plug |
Physical Specifications |
|
Depth |
57.1 cm (22.48 inches) |
Height |
34.9 cm (13.74 inches) |
Width |
51.4 cm (20.24 inches) |
Weight |
20.4 kg ( 44.97 lb ) |