FLIR E30 Thermal Imaging Infrared Camera
Description
Detect electrical overloading, energy waste, overheated equipment, moisture intrusion, and other hidden problems instantly with the speed and feature-rich performance of E-Series thermal imaging.
Features
- High Resolution IR Images – 19,200 pixels (160 x 120) Infrared resolution
- Automatic Hot/Cold detection
- Isotherm – Detect High/Low temperature interval
- Bright LED Light – Allows the visual camera and fusion to be used in poorly lit environments
- Wide Temperature Range – From -20˚ to +250˚C targeting electrical and industrial applications
- ± 2% Accuracy – reliable temperature measurement
- Thumbnail Image Gallery – Allows quick search of stored images
- Li-Ion Rechargeable Battery – lasts >4hrs continuous use; replaceable
- Copy to USB – Easy upload of images from camera to USB memory stick
- Laser LocatIR™ Pointer – Pinpoints a reference spot with a laser
- Laser Marker – Marks the point on the IR displayed image as to where the Laser pointer is targeting
- IR Window Correction – Software settings allow you to account for transmission loss through IR windows
- Area (Min/Max) Mode – Shows the Minimum or the Maximum Temperature reading within the selected area
- Auto Hot/Cold Spot Marker – Marks the area that automatically finds the hottest or coldest spot within the box
Specifications
Imaging and optical data |
Field of view (FOV) / Minimum focus distance |
25° × 19° / 0.4 m (1.31 ft.) |
Spatial resolution (IFOV) |
2.72 mrad |
|
Thermal sensitivity/NETD |
< 0.1°C @ +30°C (+86°F) / 100 mK |
|
Image frequency |
60 Hz |
|
Focus |
Manual |
|
Focal Plane Array (FPA) / Spectral range |
Uncooled micro bolometer / 7.5–13 μm |
|
IR resolution |
160 × 120 pixels |
|
Image presentation |
Display |
Touch screen, 3.5 in. LCD, 320 × 240 pixels |
Image modes |
IR image, thumbnail gallery |
|
Measurement |
Object temperature range |
–20°C to +120°C , 0°C to +250°C |
Accuracy |
±2°C (±3.6°F) or ±2% of reading |
|
Measurement analysis |
Spotmeter |
1 |
Area |
Box with max./min./average |
|
Automatic hot/cold detection |
Auto hot or cold spotmeter markers within area |
|
Isotherm |
Detect high/low temperature/interval |
|
Reference temperature |
Manually set or captured from any measurement function |
|
Emissivity correction |
Variable from 0.01 to 1.0 or selected from materials list |
|
External optics/windows correction |
Automatic, based on inputs of optics/window transmission and temperature |
|
Measurement corrections |
Reflected temperature, optics transmission and atmospheric transmission |
|
Set-up |
Color palettes |
Arctic, Gray, Iron, Lava, Rainbow and Rainbow HC |
Set-up commands |
Local adaptation of units, language, date and time formats |
|
Languages |
21 |
|
Storage of images |
Image storage |
Standard JPEG, including measurement data, on memory card |
Image storage mode |
IR images |
|
Data communication interfaces |
Interfaces |
USB-Mini, USB-A, Composite video |
USB |
• USB-A: Connect external USB device |
|
• USB Mini-B: Data transfer to and from PC |
||
Video Out |
Composite |
|
Power system |
Battery |
Li Ion, 4 hours operating time |
Charging system |
In camera (AC adapter or 12 V from a vehicle) or 2-bay charger |
|
Power management |
Automatic shutdown and sleep mode (user selectable) |
|
Environmental data |
Operating temperature range |
–15°C to +50°C (+5°F to +122°F) |
Storage temperature range |
–40°C to +70°C (–40°F to +158°F) |
|
Humidity (operating and storage) |
IEC 60068-2-30/24 h 95% relative humidity +25°C to +40°C (+77°F to +104°F) / 2 cycles |
|
Encapsulation |
IP 54 (IEC 60529) |
|
Bump |
25 g (IEC 60068-2-29) |
|
Vibration |
2 g (IEC 60068-2-6) |
|
Physical data |
Camera weight, incl. battery |
0.825 kg (1.82 lb.) |
Camera size |
246 × 97 × 184 mm (9.7 × 3.8 × 7.2 in.) |
|
Tripod mounting UNC |
¼”-20 (adapter needed) |