Fluke 1550C/Kit Insulation Resistance Tester Kit
Description
The new Fluke 1550C/Kit insulation resistance tester offers digital insulation testing up to 10 kV, making it ideal for testing a wide range of high voltage equipment including switchgear, motors, generators and cables.
Fluke insulation testers can now conduct the entire range of test voltages specified in IEEE 43-2000 with a best in class, 3 year warranty and CAT IV 600 V safety rating. With measurement storage and PC interface, the 1550C/Kit is a perfect tool for preventative or predictive maintenance programs designed to identify potential equipment failures before they occur.
Features
- Test voltages up to 5kV provides solutions for all applications
- CAT III 1000 V, CAT IV 600 V safety rating
- Voltage breakdown detection alerts the user that voltage is present and gives the voltage reading up to 600 V ac or dc for increased user safety
- Selectable test voltages in 50 V steps from 250 to 1000 V, and 100 V steps above 1000 V
- Measurements can be stored in up to 99 memory locations, with each location assigned a unique, user defined, label for easy recall
- Long battery life gives the user over 750 tests between charges
- Automatic calculation of Dielectric Absorption (DAR) and Polarization Index (PI) with no additional setup
- Guard system eliminates the effect of surface leakage current on high-resistance measurements
- Large digital/analog LCD for easy viewing
- Capacitance and leakage current measurement
- Ramp function for breakdown testing
- Resistance measurements up to 2TΩ
- Timer settings up to 99 minutes for timed tests
Specifications
Insulation resistance measurement |
|||
Test voltage (dc) |
Range (dc) |
Accuracy (± reading) |
|
250 V |
< 200 kΩ |
unspecified |
|
500 V |
200 kΩ |
unspecified |
|
1000 V |
< 200 kΩ |
unspecified |
|
2500 V |
< 200 kΩ |
unspecified |
|
5000 V |
< 200 kΩ |
unspecified |
|
10000 V |
< 200 kΩ |
unspecified |
|
Bar graph range |
0 to 1 TΩ |
||
Insulation test voltage accuracy |
-0 %, +10 % at 1 mA load current |
||
Induced ac mains current rejection |
2 mA maximum |
||
Charging rate for capacitive load |
5 seconds per μF |
||
Discharge rate for capacitive load |
1.5 s/μF |
||
Leakage current measurement |
Range: 1 nA to 2 mA |
Accuracy: ± (5 % + 2 nA) |
|
Capacitance measurement |
Range: 0.01 uF to 15.00 μF |
Accuracy: ± (15 % rdg + 0.03 μF) |
|
Timer |
Range: 0 to 99 minutes |
Resolution Accuracy: |
|
Live circuit warning |
Warning Range: |
Voltage Accuracy: |
|
General specifications |
|||
Display |
75 mm x 105 mm |
||
Power |
12 V lead-acid rechargeable battery, Yuasa NP2.8-12 |
||
Charger Input (AC) |
Charger Input (AC) 85 V to 250 V ac 50/60 HZ 20 VA |
||
This Class II (double insulated) instrument is supplied with a Class 1 (grounded) power cord. The protective earth terminal (ground pin) is not connected internally. The extra pin is for added plug retention only. |
|||
Dimensions |
170 mm x 242 mm x 330 mm (6.7 in x 9.5 in x 13 in) |
||
Weight |
3.6 kg (7.94 lb) |
||
Temperature (operating) |
-20 ºC to 50 ºC (-4 ºF to 122 ºF) |
||
Temperature (storage) |
-20 ºC to 65 ºC (-4 ºF to 149 ºF) |
||
Humidity |
80 % to 31 ºC decreasing linearly to 50 % at 50 ºC |
||
Altitude |
2000 m |
||
Enclosure sealing |
IP40 |
||
Input overload protection |
1000 V ac |
||
Electromagnetic compatibility |
EN 61326 |