Fluke Ti10 Thermal Imager
Description
The ultimate tool for troubleshooting and maintenance
This thermal imager is the perfect tool to add to your problem solving arsenal. Built for tough work environments, this high-performance, fully radiometric infrared camera is ideal for troubleshooting electrical installations, electro-mechanical equipment, process equipment, HVAC/R equipment and others.
IR-Fusion® Technology
See things both ways – infrared and visual (visible light) images combined together communicating critical information faster and easier – traditional infrared images are no longer enough. IR-Fusion is a patent-pending technology that simultaneously captures a digital photo in addition to the infrared image and combines it together, taking the mystery out of IR image analysis. IR-Fusion is standard on Ti10 models
Features
- Enhanced problem detection and analysis capabilities with IR-Fusion® Technology. Simply scroll through the different viewing modes quickly to better identify trouble areas in Full IR thermal, picture-in-picture, or automatic blend visual and thermal images.
- Optimized for field use in harsh work environments.
- Engineered and tested to withstand a 2 m (6.5 ft) drop—When was the last time you dropped a tool?
- Withstands dust and water—tested to an IP54 rating.
- Delivers the clear, crisp images needed to find problems fast.
- Identify even small temperature differences that could indicate problems with excellent thermal sensitivity (NETD).
- Intuitive, three-button menu is easy to use—simply navigate with the push of a thumb.
- Everything needed to get started is included.
- Adjustable hand strap for left-or right-handed use.
- Everything needed to get started is included.
- Training DVD is now included free. See how easy it is to set up your thermal imager, create professional reports with SmartView software and learn thermograph theory with step-by-step video instructions.
Specifications
Temperature |
|
Temperature measurement range (not calibrated below -10 °C) |
-20 °C to +250 °C (-4 °F to + 482 °F) |
Temperature measurement accuracy |
± 2 °C or 2 % (at 25 °C nominal, whichever is greater) |
Imaging performance |
|
Field of view |
23° x 17° |
Spatial resolution (IFOV) |
2.5 mRad |
Minimum focus distance |
Thermal lens: 15 cm (6 in) Visible (visual) light lens: 46 cm (18 in) |
Focus |
Manual |
Image frequency |
9 Hz refresh rate |
Detector type |
160 X 120 focal plane array, uncooled microbolometer |
Infrared lens type |
20 mm F = 0.8 lens |
Thermal sensitivity (NETD) |
≤ 0.13 °C at 30 °C target temp. (130 mK) |
Infrared spectral band |
7.5 μm to 14 μm |
Visual camera |
640 x 480 resolution |
Image presentation |
|
Palettes |
Ironbow, blue-red, high contrast, grey |
Level and span |
Smooth auto-scaling and manual scaling of level and span |
Minimum span (in manual mode) |
5 °C (9 °F) |
Minimum span (in auto mode) |
10 °C (18 °F) |
IR-Fusion® information |
Full infrared or picture-in-picture |
Picture-In-Picture (PIP) |
100 % IR displayed in center 320 x 240 pixels |
Full screen (PIP off) |
100 % IR displayed in center 640 x 480 LCD |
Palettes |
Ironbow, blue-red, high contrast, grey |
Image capture and data storage |
|
Storage medium |
SD memory card (2 GB memory card will store at least 1200 fully radiometric (.is2) IR and linked visual images each or 3000 basic (.bmp) IR images) |
File formats |
Non-radiometric (.bmp) or fully-radiometric (.is2) No analysis software required for non-radiometric (.bmp) files |
Export file formats w/SmartView™ software |
JPEG, BMP, GIF, PNG, TIFF, WMF, EXIF, and EMF |
General specifications |
|
Operating temperature |
-10 °C to +50 °C (14 °F to 122 °F) |
Storage temperature |
-20 °C to +50 °C (-4 °F to 122 °F) without batteries |
Relative humidity |
10 % to 95 % non-condensing |
Display |
9.1 cm (3.6 in) diagonal landscape color VGA (640 x 480) LCD with backlight (selectable bright or auto) |
Controls and adjustments |
User selectable temperature scale (°C/°F) Language selection Time/Date set |
Software |
SmartView® full analysis and reporting software included |
Batteries |
Internal rechargeable battery pack (included) |
Battery life |
Three to four hours continuous use (assumes 50 % brightness of LCD) |
Battery charge time |
Two hours for full charge |
AC operation/charging |
AC adapter/charger (110 Vac to 220 Vac, 50 Hz to 60 Hz). Charges battery while imager is operating. Universal ac mains adapters included. |
Power saving |
Sleep mode activated after five minutes of inactivity, automatic power off after 20 minutes of inactivity |
Safety standards |
CE Directive: IEC/EN 61010-1 2nd Edition Pollution Degree 2 |
Electromagnetic compatibility |
EMC directive: EN61326-1 C-Tick: IEC/EN 61326 US FCC: CFR 47, Part 15 Class A |
Vibration |
2 G, IEC 68-2-29 |
Shock |
25 G, IEC 68-2-29 {2 m (6.5 ft) drop, 5 sides} |
Dimensions (HxWxL) |
0.27 m x 0.13 m x 0.15 m (10.5 in x 5 in x 6 in) |
Weight |
1.2 kg (2.65 lb) |
IP rating |
IP54 |
Warranty |
Two-years |
Calibration cycle |
Two-years (assumes normal operation and normal aging) |
Supported languages |
Czech, English, Finnish, French. German, Italian, Japanese, Korean, Polish, Portuguese, Russian, Simplified Chinese, Spanish, Swedish, Traditional Chinese, Turkish |