Haefely Hipotronics ECOMPACT 4 Compact Transient Immunity Test System 4.2kV
Description
Haefely Hipotronics ECOMPACT 4 Compact Transient Immunity Test System 4.2kV performs all the most commonly used transient immunity tests, including Surge, EFT, Dips/Interrupts and AC/Surge Magnetic Field. The simplified user interface provides quick selection of tests and test levels, and even lets you change test parameters “on the fly” while running a test.
MODEL OVERVIEW
ECOUPLER 4 Three-Phase Coupling / Decoupling Network for ECOMPACT 4
Features
- Surge impulse voltage up to 4.2kV
- Surge impulse current up to 2.1kA
- EFT impulse voltage up to 4.2kV
- Integrated single-phase CDN 250V/16A
- Test routine storage and recall
Download Data Sheet
Print
Email
Specifications
| System Mainframe | |
| Control Power | 100/115/230V 50/60 Hz |
| Memory Storage | 20 positions |
| Communication Interface | RS232, RS485 |
| Weight | 30 kg |
| Dimensions (W x H x D) | 48 x 18 x 44 cm |
| IEC / EN 61000-4-4 Edition 2 Electrical Fast Transient | |
| Output Voltage | 0.2 – 4.2 kV |
| Polarity | Positive and Negative |
| Output Impedance | 50 Ohms |
| Rise Time | 5 ns +/- 30% |
| Impulse Duration | 50 ns +/- 30% (50 Ohms)
50 ns –15 +100 ns (1 kOhm) |
| Spike Frequency | 0.5 – 100 kHz |
| Burst Duration | 0.75 – 130 ms |
| Burst Period | 10 – 2400 ms |
| Spikes per Second | Max. 2500 at U < 3 kV
Max. 1250 at U = 3 kV to 4.2 kV |
| Integrated Single Phase Coupling Decoupling Network | 33 nF coupling capacitance
1.5 mH decoupling inductance 230V AC/60V DC, 16A |
| IEC / EN 61000-4-5 Surge Combination Wave | |
| Output Voltage | 0.2 – 4.2 kV |
| Voltage Rise Time | 1.2 us +/- 30% |
| Voltage Duration | 50 us +/- 20% |
| Polarity | Positive and Negative |
| Output Impedance | 2 Ohms |
| Synchronization | 0 – 359 deg, 1 deg res. |
| Output Current | 0.1 – 2.1 kA |
| Current Rise Time | 8 us +/- 20% |
| Current Duration | 20 us +/- 20% |
| Repetition Rate | 10 s – 999 s |
| Integrated Single Phase Coupling / Decoupling Network | 230V AC / 60V DC, 16A
According to IEC/EN 61000-4-5 Edition 1 & 2 |
| IEC / EN 61000-4-11 Edition 1 & 2 and IEC / EN 61000-4-29 Dips and Interrupts | |
| Max. Voltage | 250V AC/DC |
| Max. Current | 16A AC/DC |
| Dip Levels | 0%, 40%, 70%, 80% |
| Interrupt Time | 0.1 ms – 998 s |
| Repetition Time | 0.2 ms – 999 s |
| Phase Synch. | 0 – 359 degree asynchronous
16 / 40 / 50 / 60 Hz |
- ANSI/IEEE Standards
- ANSI/IEEE C62.41
- Basic Standards
- IEC 61000-4-10
- IEC 61000-4-11
- IEC 61000-4-29
- IEC 61000-4-4
- IEC 61000-4-5
- IEC 61000-4-8
- IEC 61000-4-9
- Product Standards
- EN 300 386-2 V1.1.3
- EN 50370-1
- EN 61643
- IEC 60255-1
- IEC 60601-1-2
- IEC 61326-1
- IEC 61850-3
- EN 301 489-1
- EN 301 489-17
- EN 301 489-24
- EN 301 489-7
- Generic Standards
- EN 61000-6-1
- EN 61000-6-2