Haefely Hipotronics PEFT 4010 EFT/Burst Immunity Test System 4.8kV

Description

Haefely Hipotronics PEFT 4010 EFT/Burst Immunity Test System is used to measure the most common sources of disturbances in modern electronic circuits. EFT/bursts are caused by the operation of electro-mechanical switches, motors or power distribution switchgears and are generated according to the IEC/EN 61000-4-4.

The PEFT 4010 instrument contains all the features expected from an EFT generator. It can either be operated by the front panel keys in a standalone manner or be controlled by PC via RS232 or IEEE 488 as part of a complete EMC test system.

Features

  • EFT impulse generation
  • ESD control and report functions
  • Automatic test operation
  • Data exchange
  • Compact and reliable construction
  • Remote control
  • ISO 9001:2000
Download Data Sheet
Print
Email

Specifications

Wave Shape into 50Ω load
Rise time 5 ns ± 30 %
Impulse duration 50 ns ± 30 %
Wave Shape into 1000Ω load
Rise time 5 ns ± 30 %
Impulse duration 50 ns – 15 / + 100 ns
Burst Characteristic
Voltage range 0.22 … 4.8 kV

(0.1 … 4.8 kV in expanded mode)

Spike frequency 1 Hz … 1 MHz

(1 Hz … 2 MHz in expanded mode)

Burst duration 0.01 … 999 ms
Burst period 0.1 Hz … 400 Hz

2.5 ms … 10 s

1 period … 500 periods

Impulses per second Max. 12’000
Impulses per burst Max. 1’000
Spike distribution normal, continuous, random, real (real5, real100 with “Real

Burst” option)

Polarity positive, negative
Test time 10 s … 8 h per path
Single Phase Coupling/Decoupling Network
Maximum AC voltage 264 V @ 16 … 440 Hz
Maximum AC current 16 A @ 50 … 60 Hz, 10 A @ 400 Hz
Maximum DC voltage 125 V
Maximum DC current 16 A (dependant on DC voltage)
Coupling Modes L-GND, N-GND, PE-GND, LN-GND, LPE-GND, NPEGND, LNPE-GND
Residual voltage at Test Supply Input ≤ 10% of applied test voltage
Synchronization
Frequency 16 2/3 Hz, 40 Hz, 50 Hz, 60 Hz, 400 Hz, auto
Impulse trigger automatic, manual, external
System Configuration
EUT fail input BNC, logic low to trigger
P90 interface for a 3-phase CDN extension
PESD interface for connecting an ESD generator
Printer interface Centronix
Computer interface RS-232, IEEE-488 (optional)
Power Supply
Voltage 85 … 264 VAC, 150 VA
Frequency 50 / 60 Hz
Weight and Dimension
Weight 14 kg
W x H x D 450mm x 130mm x 570mm
Stay informed