Haefely Hipotronics PSURGE 8000 Surge Platform Test System
Description
Haefely Hipotronics PSURGE 8000 Surge Platform Test System meets all your current and future surge testing requirements. A modular expandable system that grows with your application needs. The modular concept is built around a PC based host controller (the PSURGE 8000 controller) with physically and functionally independent modules for impulses (PIM #X) and coupling/decoupling (PCD #X). The system uses distributed intelligence and each module has its own application-specific program, runs internal routines and communicates with the host controller.
IMPULSE MODULES OVERVIEW
PIM 100 Surge Combination Wave Impulse Module
PIM 110 Surge Ring Wave Impulse Module
PIM 120 Telecom Wave Impulse Module 10/700us
PIM 130 Voltage Impulse Module 1.2/50µs
PIM 150 Surge Damped Oscillatory Wave Impulse Module 100 kHz & 1 MHz
PIM 155 Oscillating Magnetic Field Module 100 kHz & 1 MHz
PIM 200 Current Impulse Module 8/20µs and 10/1000µs
Features
- PIM #X modules cover the most common surge standards, such as EN, ETSI, IEC, Telcordia (Bellcore), FCC (TIA) 68, UL, ITU, ANSI, IEEE & more
- Customized Waveform can be easily realized and integrated in a new or existing PSURGE 8000 system
- Compatible with various Coupling/Decoupling networks for power lines 1 Phase and 3 Phase up to 690V / 100A
- A selection of Coupling network for data & signal lines up to 24 outputs are on-hand
- Test routine Storage and Recall, up to 36 tests & programs
Specifications
IMPULSE MODULES | |
PIM 100 Combination wave impulse module | Built according to IEC/EN 61000-4-5 Ed. 1 & 2 and ANSI C62.41/45 |
1.2/50 μs open circuit up to 7.4 kV | |
8/20 μs short circuit up to 3.7 kA | |
Impulse voltage and current monitors | |
± 1° phase synchronization | |
Reliable semiconductor HV-switch | |
Positive, negative and alternating polarity | |
Up to 12 pulses per minute | |
PIM 110 Ring wave impulse module | Built according to IEC/EN 61000-4-12 and ANSI C62.41/45 |
100 kHz frequency, 0.5 μs rise time | |
Imp. voltage up to 7.8 kV / 12 Ω, 30 Ω and 200 Ω | |
Impulse voltage and current monitors | |
± 1° phase synchronization | |
Positive, negative and alternating polarity | |
Up to 12 pulses per minute | |
Reliable semiconductor HV-switch | |
PIM 120 Telecom wave impulse module | Built according to IEC/EN 61000-4-5 Ed. 1 & 2, ITU K-series and IEC 60950 |
10/700 μs open circuit voltage | |
5/320 μs short circuit current | |
Imp. voltage up to 7.4 kV / 15 Ω and 40 Ω | |
Impulse voltage & current monitors | |
Reliable semiconductor HV-switch | |
Positive, negative and alternating polarity | |
Up to 12 pulses per minute | |
PCD 120 Four-wire coupling unit for telecom wave | 4 wire coupling unit for unshielded symmetrical operated lines |
Compliant with IEC 61000-4-5 (10/700 μs impulse only), ITU K.20 / K.21 / K.44 / K.45 | |
Fully automated operation | |
PIM 150 Oscillating wave impulse module | Built according to IEC/EN 61000-4-12 Ed.1, IEC 61000-4-18 Ed.1, IEC 60255-22-1 and ANSI C37.90 |
100 kHz and 1 MHz burst frequencies | |
75 ns rise time | |
Impulse voltage up to 3.3 kV / 200 Ω | |
Integrated, fully automatic CDN for three-phase AC and DC power lines | |
EUT mains voltage up to 480 V / 277 V 16 A | |
Impulse voltage monitor | |
Capacitive coupling clamp available optionally (IP 4 A) | |
Data line CDN available optionally (PCD 150) | |
COUPLING / DECOUPLING NETWORKS | |
PCD 100 Single phase CDN for combination & ring wave | Built according to IEC/EN 61000-4-5 Edition 1 & 2 ANSI C62.41/45, TIA-968A (FCC part 68/47 CFR), Telcordia (Bellcore) GR 1089 CORE |
Fully automated test routines | |
Coupling of up to two different wave-shapes without any rewiring | |
For combination wave, ring wave and others (PIM 100, PIM 110) | |
Up to 8 kV impulse voltage | |
EUT mains up to 264 V / 16 A | |
PCD 130 Three phase CDN for combination and ring wave | Built according to IEC/EN 61000-4-5 Edition 1 & 2 ANSI C62.41/45, TIA-968A (FCC part 68/47 CFR), Telcordia (Bellcore) GR 1089 CORE |
Fully automated test routines | |
Coupling of up to three different wave- shapes without any rewiring | |
For combination wave, ring wave and others | |
Up to 8 kV impulse voltage | |
EUT mains voltage up to 690 V / 400 V | |
EUT mains current up to 32 A per phase | |
Correct phase angle synchronization for each coupling path |
- ANSI/IEEE Standards
- ANSI/IEEE C62.41
- Basic Standards
- IEC 61000-4-11
- IEC 61000-4-12
- IEC 61000-4-29
- IEC 61000-4-4
- IEC 61000-4-5
- IEC 61000-4-8
- IEC 61000-4-9
- Telecom Standards
- Telcordia GR-1089
- ITU-T K.12
- ITU-T K.20
- ITU-T K.21
- ITU-T K.28
- ITU-T K.41
- ITU-T K.44
- ITU-T K.45
- TIA-968-B
- Product Standards
- EN 300 386 V1.3.2
- EN 300 386-2 V1.1.3
- EN 50082-1
- EN 50082-2
- EN 50370-1
- EN 61643
- FCC 97-270 (Part 68)
- IEC 60255-1
- IEC 60601-1-2
- IEC 61009-1
- IEC 61326-1
- IEC 61850-3
- EN 301 489-1
- EN 301 489-17
- EN 301 489-24
- EN 301 489-7
- Generic Standards
- EN 61000-6-1
- EN 61000-6-2
- Automotive OEM Specifications
- UNECE R10 (Automotive)