Kikusui PCR500L Regulated Single Phase AC Power Supply

Description

The PCR-LA Series is the most advanced, with having polished multifunctional AC power supply device of our best selling AC power supply PCR-L Series. By adding new functions and options while carrying over the basic performance from former model, this Series is reborn as a safe and reliable model that is much easier to use. As the PCR-LA Series comes with not only the basic operating functions of the main body, but also has standard equipment of RS-232C and the dedicated remote control external interface (GPIB is optional), if you have a PC, you can use almost all of the functions of the PCR-LA Series. The remote controller (RC03-PCR-LA) is available for abnormal power line simulation functions, which is the most frequently used in power supply environment testing, it makes possible for you to perform the functions easily, and above all, at a low cost.

With the PCR-LA Series' high-quality basic performance and abundance in flexible expandability, apply to the anticipated fields of various applications, in the field of electric, machinery and chemicals for such power supply environmental testing, immunity testing, or power amplification of the output waveform for arbitrary waveform signal generators.

 

Features

  • High-quality/high-stability output with a high-speed linear amp
  • Equipped with various measuring functions
  • Offering also DC outputs
  • Come with the RS-232C and remote control interface are standard equipment
  • Low frequency immunity test software (option)
Download Data Sheet
Print
Email

Specifications

Input Ratings (RMS Values)

Voltage

85 to 132V / 170 to 250V (100V or 200V range)

No. Phase, Frequency

Single Phase 47 to 63Hz

Apparent Electrical Power

Approx. 1kVA

Power Factor

                0.95 typical

Current (100V or 200V range)

12A / 6A or less

Output Ratings – AC Mode (RMS Values)

Voltage

1 to 150V/2 to 300V (100V or 200V range)

Max. Current

5A/2.5A

No. Pases

1

Power Capacity

500VA

Max. Peak Current

4 times max. current (RMS value)

Load Power Factor

0 to 1 (advanced or delayed phase)

Frequency

1 to 999.9Hz

Output Voltage Waveform Distortion

Max.0.3%

Output Rating – DC Mode           

Voltage

+-1.4 to 212V/}2.8 to }424V

Max. Current

2.5/1.25A

Power Capacity

250VA

Indicators (Display Mode)

Voltmeter (RMS, PEAK,AVE)

Ammeter (RMS, PEAK, AVE)

Power Meter, Frequency Meter

Circuitry

Linear amp type

Operating Temperature and Humidity Ranges

0 to + 50°C/10 to 90% RH (no condensation of dew)

Dimensions

430 × 217 × 550 mm

Weight

Approx 25 kg