Rohde & Schwarz BBA150-series Broadband Amplifiers 4 kHz – 6 GHz up to 3000W
Description
Rohde & Schwarz BBA150-series Broadband Amplifiers 4 kHz – 6 GHz can be used to address a variety of applications, including the various standards for EMS measurements up to 6 GHz. The R&S®BBA150 is ideal for amplitude, frequency, phase and pulse modulation. It’s suitable for development and product validation tests in quality assurance and in the development and production of components. Other fields of use include research, physical engineering and communications.
Features
- Frequency bands: 9 kHz to 250 MHz; 4 kHz to 400 MHz; 80 MHz to 1.0 GHz; 0.69 GHz to 3.2 GHz; 2.5 GHz to 6.0 GHz
- Output power from 15 W to 3000 W
- 100 % mismatch tolerance
- Suitable for amplitude, frequency, phase and pulse modulation
- Reliable with high availability
- Flexible control and operation
Download Data Sheet
Print
Email
Specifications
RF specifications | ||
Amplifier type | class A | |
Frequency bands | 9 kHz to 250 MHz, instantaneously
4 kHz to 400 MHz 80 MHz to 1.0 GHz, instantaneously 0.69 GHz to 3.2 GHz, instantaneously 2.5 GHz to 6.0 GHz, instantaneously |
|
Nominal output power | 9 kHz to 250 MHz | 125 W to 2500 W |
4 kHz to 400 MHz | 75 W to 600 W | |
80 MHz to 1.0 GHz | 70 W to 3000 W | |
0.69 GHz to 3.2 GHz | 30 W to 800 W | |
2.5 GHz to 6.0 GHz | 15 W to 400 W | |
Nominal output load | 50 Ω | |
Gain flatness | ±4.0 dB (or better; see data sheet) | |
Gain adjustment range | > 15 dB | |
Modulation capability | AM, FM, φM, PM | |
Nominal input impedance | 50 Ω | |
Max. RF input level | max. +15 dBm | |
Max. RF input level (9 kHz to 250 MHz) | max. +5 dBm | |
Input level for nominal output power | –3.4 dBm | |
Nominal output impedance | 50 Ω | |
Output mismatch tolerance, VSWR | 100 %, without damage | |
RF and sample connectors | ||
RF input port | N female | |
RF output port | N female, 7/16 DIN female or 1 5/” EIA female | |
RF sample ports | forward output power, optional | N female |
reflected output power, optional | N female | |
Detected sample ports | forward output power, optional | N female |
reflected output power, optional | N female | |
Graphical user interface | ||
Local graphical display | 200 × 48 pixels, monochrome | |
Web GUI via Ethernet | RJ-45, 10/100 Mbit/s, autonegotiation, half/full duplex | |
General data | ||
Operating voltage range | R&S®BBA150-A125 to -A200/-AB75 to -AB200/-BC70 to -BC250/-D30 to -D110/-E15 to -E100 | 100 V to 240 V AC ± 10 %, single phase, 50 Hz to 60 Hz ± 6 % |
R&S®BBA150-A400/-AB350/-D200/-E200 | 120 V to 240 V AC ± 10 %, single phase, 50 Hz to 60 Hz ± 6 % | |
R&S®BBA150-A700/-AB600/-BC500/-BC1000/-D400/-E400 | 200 V to 240 V AC ± 10 %, single phase, 50 Hz to 60 Hz ± 6 % | |
R&S®BBA150-A1300/-A2500/-BC1250 to -BC3000/-D800 | 380 V to 415 V AC ± 10 %, three phase, with N, 50 Hz to 60 Hz ± 6 % | |
Air cooling | forced air, built-in fans, air entry at front, air exit at rear | |
Dimensions | ||
Desktop model | incl. fans, handles and feet; W × H × D | 430 mm × 196 mm × 580 mm
(16.93 in × 7.72 in × 22.83 in) |
for rack mounting | 19″ 1/1, 4 HU | |
Rack models (W × H × D) | R&S®BBA150-A700/-BC1000/-D400/-E400 | 19″ × 12 HU × 800 mm (31.5 in) |
R&S®BBA150-D800 | 19″ × 20 HU × 800 mm (31.5 in) | |
R&S®BBA150-A1300/-BC1250/-BC1500/-BC2000 | 19″ × 20 HU × 1000 mm (39.4 in) | |
R&S®BBA150-A2500 | 19″ × 35 HU × 800 mm (31.5 in) | |
R&S®BBA150-BC3000 | 19″ × 35 HU × 1000 mm (39.4 in) |