Rohde & Schwarz FPL1000-series Spectrum Analyzers 5 kHz – 7.5 GHz
Description
Rohde & Schwarz FPL1000-series Spectrum Analyzers 5 kHz – 7.5 GHz make measuring fast and simple. The intuitive touchscreen is straightforward and easy to use. With its solid RF performance, light weight and small footprint, the R&S®FPL1000 combines the functionality of a benchtop instrument with the portability of a handheld instrument.
MODEL OVERVIEW
FPL1003 Spectrum Analyzer 5 kHz to 3 GHz
FPL1007 Spectrum Analyzer 5 kHz to 7.5 GHz
Features
- Frequency range 5 kHz to 3 GHz or 7.5 GHz
- SSB phase noise: typ. –108 dBc (1 Hz) at 10 kHz (1 GHz carrier) offset
- DANL with preamplifier: typ. –166 dBm from 10 MHz to 2 GHz
- Lightweight with small footprint
- 40 MHz analysis bandwidth (option)
Specifications
Frequency | ||
Frequency range | R&S®FPL1003 | 5 kHz to 3 GHz |
R&S®FPL1007 | 5 kHz to 7.5 GHz | |
Frequency resolution | 0.01 Hz | |
Bandwidth | ||
Resolution bandwidth (–3 dB) | sweep filters | 100 kHz to 10 MHz in 1/2/3/5 sequence |
FFT filters | 1 Hz to 50 kHz in 1/2/3/5 sequence | |
Signal analysis bandwidth (equalized) | standard | nom. 10 MHz |
with R&S®FPL1-B40 option | nom. 40 MHz | |
Displayed average noise level (DANL) | ||
RF preamplifier off | 5 kHz ≤ f < 100 kHz | typ. –143 dBm |
100 kHz ≤ f < 5 MHz | < –140 dBm, typ. –143 dBm | |
5 MHz ≤ f < 3 GHz | < –149 dBm, typ. –152 dBm. | |
3 GHz ≤ f < 5 GHz | < –143 dBm, typ. –146 dBm | |
5 GHz ≤ f ≤ 7.5 GHz | < –140 dBm, typ. –143 dBm | |
RF preamplifier on (gain nom. 20 dB) | 3 MHz ≤ f < 10 MHz | < –155 dBm, typ. –158 dBm |
10 MHz ≤ f < 2 GHz | < –163 dBm, typ. –166 dBm | |
2 GHz ≤ f < 3 GHz | < –162 dBm, typ. –165 dBm | |
3 GHz ≤ f < 5 GHz | < –158 dBm, typ. –161 dBm | |
5 GHz ≤ f < 7 GHz | < –156 dBm, typ. –159 dBm | |
7 GHz ≤ f < 7.5 GHz | < –155 dBm, typ. –158 dBm | |
Attenuation and Gain | ||
Setting range of attenuator | standard | 0 dB to 45 dB, in 5 dB steps |
with R&S®FPL1-B25 option | 0 dB to 45 dB, in 1 dB steps | |
PRF preamplifier gain | with R&S®FPL1-B22 option | nom. 20 dB |
Intermodulation | ||
1 dB compression of input mixer (two-tone) | RF attenuation 0 dB, RF preamplifier = off | nom. +7 dBm |
Third-order intercept point (TOI) | RF attenuation 0 dB, level 2 × –20 dBm, ∆f > 5 × RBW or 10 kHz, whichever is larger, RF preamplifier = off | |
10 MHz ≤ fin < 300 MHz | > 13 dBm, typ. 16 dBm | |
300 MHz ≤ fin < 3 GHz | > 17 dBm, typ. 20 dBm | |
3 GHz ≤ fin ≤ 7.5 GHz | > 15 dBm, typ. 18 dBm | |
with R&S®FPL1-B22 option, RF attenuation 0 dB, level 2 × –40 dBm, ∆f > 5 × RBW or 10 kHz, whichever is larger, RF preamplifier = on |
||
5 MHz ≤ fin < 7,5 GHz | nom. 0 dBm | |
Phase noise | ||
SSB phase noise | frequency = 1000 MHz, carrier offset | |
100 Hz | nom. –88 dBc (1 Hz) | |
1 kHz | < –99 dBc (1 Hz) | |
10 kHz | < –105 dBc (1 Hz), typ. –108 dBc (1 Hz) | |
100 kHz | < –110 dBc (1 Hz), typ. –115 dBc (1 Hz) | |
1 MHz | < –130 dBc (1 Hz), typ. –135 dBc (1 Hz) | |
10 MHz | nom. –152 dBc (1 Hz) | |
Overall Amplitude Accuracy | ||
Total measurement uncertainty | signal level 0 dB to –50 dB below reference level, S/N > 20 dB, sweep time auto, sweep type = FFT, RF attenuation 10 dB, 20 dB, 30 dB, 40 dB, RF preamplifier = off, span/RBW < 100, confidence level 95 %, +20 °C to +30 °C |
0.5 dB |
1 MHz ≤ f < 3 GHz | 0.5 dB | |
3 GHz ≤ f < 7.5 GHz | 0.8 dB |