Rohde & Schwarz FPL1000-series Spectrum Analyzers 5 kHz – 7.5 GHz

Description

Rohde & Schwarz FPL1000-series Spectrum Analyzers 5 kHz – 7.5 GHz make measuring fast and simple. The intuitive touchscreen is straightforward and easy to use. With its solid RF performance, light weight and small footprint, the R&S®FPL1000 combines the functionality of a benchtop instrument with the portability of a handheld instrument.

 

MODEL OVERVIEW

FPL1003 Spectrum Analyzer 5 kHz to 3 GHz
FPL1007 Spectrum Analyzer 5 kHz to 7.5 GHz

Features

  • Frequency range 5 kHz to 3 GHz or 7.5 GHz
  • SSB phase noise: typ. –108 dBc (1 Hz) at 10 kHz (1 GHz carrier) offset
  • DANL with preamplifier: typ. –166 dBm from 10 MHz to 2 GHz
  • Lightweight with small footprint
  • 40 MHz analysis bandwidth (option)
Download Data Sheet
Print
Email

Specifications

Frequency
Frequency range R&S®FPL1003 5 kHz to 3 GHz
R&S®FPL1007 5 kHz to 7.5 GHz
Frequency resolution   0.01 Hz
Bandwidth
Resolution bandwidth (–3 dB) sweep filters 100 kHz to 10 MHz in 1/2/3/5 sequence
FFT filters 1 Hz to 50 kHz in 1/2/3/5 sequence
Signal analysis bandwidth (equalized) standard nom. 10 MHz
with R&S®FPL1-B40 option nom. 40 MHz
Displayed average noise level (DANL)
RF preamplifier off 5 kHz ≤ f < 100 kHz typ. –143 dBm
100 kHz ≤ f < 5 MHz < –140 dBm, typ. –143 dBm
5 MHz ≤ f < 3 GHz < –149 dBm, typ. –152 dBm.
3 GHz ≤ f < 5 GHz < –143 dBm, typ. –146 dBm
5 GHz ≤ f ≤ 7.5 GHz < –140 dBm, typ. –143 dBm
RF preamplifier on (gain nom. 20 dB) 3 MHz ≤ f < 10 MHz < –155 dBm, typ. –158 dBm
10 MHz ≤ f < 2 GHz < –163 dBm, typ. –166 dBm
2 GHz ≤ f < 3 GHz < –162 dBm, typ. –165 dBm
3 GHz ≤ f < 5 GHz < –158 dBm, typ. –161 dBm
5 GHz ≤ f < 7 GHz < –156 dBm, typ. –159 dBm
7 GHz ≤ f < 7.5 GHz < –155 dBm, typ. –158 dBm
Attenuation and Gain
Setting range of attenuator standard 0 dB to 45 dB, in 5 dB steps
with R&S®FPL1-B25 option 0 dB to 45 dB, in 1 dB steps
PRF preamplifier gain with R&S®FPL1-B22 option nom. 20 dB
Intermodulation
1 dB compression of input mixer (two-tone) RF attenuation 0 dB, RF preamplifier = off nom. +7 dBm
Third-order intercept point (TOI) RF attenuation 0 dB, level 2 × –20 dBm, ∆f > 5 × RBW or 10 kHz, whichever is larger, RF preamplifier = off
10 MHz ≤ fin < 300 MHz > 13 dBm, typ. 16 dBm
300 MHz ≤ fin < 3 GHz > 17 dBm, typ. 20 dBm
3 GHz ≤ fin ≤ 7.5 GHz > 15 dBm, typ. 18 dBm
with R&S®FPL1-B22 option, RF attenuation 0 dB, level 2 × –40 dBm,
∆f > 5 × RBW or 10 kHz, whichever is larger, RF preamplifier = on
5 MHz ≤ fin < 7,5 GHz nom. 0 dBm
Phase noise
SSB phase noise frequency = 1000 MHz, carrier offset  
100 Hz nom. –88 dBc (1 Hz)
1 kHz < –99 dBc (1 Hz)
10 kHz < –105 dBc (1 Hz), typ. –108 dBc (1 Hz)
100 kHz < –110 dBc (1 Hz), typ. –115 dBc (1 Hz)
1 MHz < –130 dBc (1 Hz), typ. –135 dBc (1 Hz)
10 MHz nom. –152 dBc (1 Hz)
Overall Amplitude Accuracy
Total measurement uncertainty signal level 0 dB to –50 dB
below reference level, S/N > 20 dB,
sweep time auto, sweep type = FFT,
RF attenuation 10 dB, 20 dB,
30 dB, 40 dB, RF preamplifier = off,
span/RBW < 100, confidence level 95 %,
+20 °C to +30 °C
0.5 dB
1 MHz ≤ f < 3 GHz 0.5 dB
3 GHz ≤ f < 7.5 GHz 0.8 dB