Rohde & Schwarz HZ-14 Near Field Probe Set 9 kHz – 1 GHz

Description

Rohde & Schwarz HZ-14 Near Field Probe Set 9 kHz – 1 GHz is a tool for detecting EMC trouble spots. It allows the identification and elimination of disturbance sources as well as the detection of spots sensitive to electromagnetic interference at an early stage of product development, which reduces the time to market.

The HZ-14 is mainly used for diagnosing radiated emissions from printed boards, ICs, cables, leakage spots in shielded enclosures and similar sources of electromagnetic interference. Radiated emission sources can be easily located owing to the small size of the probe tips.

Features

  • Passive H-field probe from 9 kHz to 30 MHz
  • Passive H-field probe from 30 MHz to 1 GHz
  • Active E-field probe from 9 kHz to 1 GHz
  • 30 dB broadband preamplifier for H-field probes from 9 kHz to 1 GHz
  • DC supply to operate the E-field probe
  • Test jig to allow functional testing of the H-field probes
  • DC power to E-field probe and preamplifier is supplied by Rohde & Schwarz measuring receivers and spectrum analyzers
Download Data Sheet
Print
Email

Specifications

H-field probe (9 kHz to 30 MHz)
Frequency range 9 kHz to 30 MHz
Usable frequency range 9 kHz to 100 MHz
Maximum permissible voltage of uninsulated conductor 0 Hz to 120 Hz 500 V (Vp)
Maximum input power EMS testing 0.5 W
RF connector SMA female
Dimensions
W × H × D (including RF connector) 256 mm × 38 mm × 18 mm

(10.1 in × 1.5 in × 0.7 in)

H-field probe (30 MHz to 1 GHz)
Frequency range 30 MHz to 1 GHz
Usable frequency range 1 MHz to 2 GHz
Maximum permissible voltage of uninsulated conductor 0 Hz to 120 Hz 500 V (Vp)
Maximum input power EMS testing 0.25 W
RF connector SMA female
Dimensions
W × H × D (including RF connector) 256 mm × 38 mm × 18 mm

(10.1 in × 1.5 in × 0.7 in)

E-field probe (9 kHz to 1 GHz)
Frequency range 9 kHz to 1 GHz
Frequency response ±3 dB
Antenna factor with capacitive coupling 13 mV/V
Antenna factor typ. 67 dB (1/m)
Maximum permissible voltage at probe tip 20 V
RF connector SMA female
Dimensions
W × H × D (including RF connector) 267 mm × 38 mm × 18 mm

(10.5 in × 1.5 in × 0.7 in)

DC supply
Required DC voltage with E-field probe 10/15 V ± 0.1 V
DC connector LEMO (2 contacts with screen)
RF connector input BNC female
RF connector output N male
Dimensions
W × H × D (including RF connector) 97 mm × 26 mm × 28 mm