Sorensen DCS 40-25E Programmable DC Power Supply 40V 25A 1000W

Description

Sorensen DCS 40-25E Programmable DC Power Supply 40V 25A 1000W is ideally suited for a wide range of applications requiring DC power in a small form factor. Applications range from manufacturing test and burn-in of automotive components, avionics electronics, telecommunications and consumer products to beam steering, process control and laboratory R&D use.

The DCS Family of 1 kW, 1.2 kW and 3 kW programmable power supplies utilizes unique packaging techniques to achieve continuous full output power (1 kW, 1.2 kW or 3 kW) in any volt/amp combination within the rated output voltage and current limits in a low profile chassis, Demonstrated large installed base over a long period of time, the DCS family provides a highly reliable power platform.

This family has an easy-to-use front panel with 10-turn potentiometers to adjust voltage and current settings that are displayed simultaneously. LEDs indicate overtemperature, remote programming, shutdown and over voltage protection, status and constant-voltage/current mode operation. The DCS 3 kW Models have push button control of the output standby mode, OVP reset, remote/local programming and preview status of voltage, current and OVP setpoints.

The DCS family can also be controlled remotely. Four analog control modes are standard as well as isolated analog control (option). Computer control can be accomplished over IEEE488.2 GPIB (option) or LXI-compliant Ethernet (option).

Features

  • High power density / low ripple and noise
  • High programming resolution with Ethernet interface
  • Constant voltage and current mode
  • Remote sensing
  • Isolated analog control and monitoring (optional)
Download Data Sheet
Print
Email

Specifications

Common
Meter Accuracy 1% of full scale + 1 count
Max. Voltage Differential from Output to Safety Ground 150 VDC
Remote Start/Stop and Interlock TTL compatible input or 12-250 VAC (12-130 VDC) or a contact closure
Cooling Internal fan, over temperature shutdown if internal heat sink exceeds set temperature
Remote Sense The maximum allowed sense line drop is 4V per line (2V on the DCS 8/10V 1 kW/1.2 kW models and 1V/line for all 3 kW models). Line drop subtracts from the maximum available output voltage at full rated power.
Remote Programming Enabled via external jumper on rear panel connector J3
Overvoltage Protection Crowbar type adjustable from 5-110% of rated output using front panel control (local or remote program selectable via J3 jumper)
Remote Analog Programming Linearity ±1% Accuracy: ±5%
Regulatory Certified to UL/CSA 61010 and IEC/EN 61010-1 CE Compliant (LVD and EMC directive)
Input: Voltage and Frequency
Output Power

200 – 250 VAC

100 – 132 VAC

1kW

single phase, 8A typical, 47- 63 Hz

single phase, 15A typical, 47-63 Hz, internal jumper selectable

Output: Voltage and Current
1kW Model

Voltage

Current

DCS 8-125E

0 – 8

0 – 125

DCS 10-100E

0 – 10

0 – 100

DCS 20-50E

0 – 20

0 – 50

DCS 33-33E

0 – 33

0 – 33

DCS 40-25E

0 – 40

0 – 25

DCS 50-20E

0 – 50

0 – 20

DCS 60-18E

0 – 60

0 – 18

DCS 80-13E

0 – 80

0 – 13

DCS 100-10E

0 – 100

0 – 10

DCS 150-7E

0 – 150

0 -7

DCS 300-3.5E

0 – 300

0 – 3.5

DCS 600-1.7E

0 – 600

0 – 1.7

Output
Voltage Resolution 0.02%
Ripple (mV rms or p-p) See table
Regulation Line For input voltage variation over the AC input voltage range, with constant rated load.
Load For 0-100% load variation, with constant nominal line voltage.
Voltage 0.1%
Current 0.1%
Transient Response Typically recovers in 500 μs (1 & 1.2 kW) or 1ms (3k W) to 1% of steady-state output voltage (within 1% of Vmax) for 70-100% or 100-70% load change.
Stability ±0.05% of maximum voltage or current over 8 hours after 30 minute warm-up time at fixed line, load and temperature
Efficiency See table below Temperature Coefficient: 0.02%/°C of maximum output voltage; 0.03%/°C of maximum output current. Change in output per °C change in ambient temperature, with constant line and load
Physical
Dimensions Width: 19” (482 mm) W, Depth 17.52” (445 mm)

Height: 1 kW and 1.2 kW: 1U or 1.72”

Weight & Shipping Weight
Weight 1 kW and 1.2 kW: 19 lbs. ( 8.6 kg)
Shipping Weight 1 kW and 1.2 kW: 24 lbs. (10.9 kg)
Environmental
Operating Temperature 0°C to 50°C (no derating)
Storage Temperature -55°C to 85°C
Humidity Range 0 to 80% RH, non condensing
Programming Specifications
DCS Series 1 kW

Programming Accuracy M130/M131/M9C/M85 Options

Voltage 0.1% +

Current 0.1% +

OVP 0.5% +

DCS 8-125E

8mV

500mA

44mV

DCS 10-100E

10mV

400mA

55mV

DCS 20-50E

20mV

200mA

110mV

DCS 33-33E

33mV

132mA

182mV

DCS 40-25E

40mV

100mA

220mV

DCS 50-20E

50mV

80mA

275mV

DCS 60-18E

60mV

72mA

330mV

DCS 80-13E

80mV

52mA

440mV

DCS 100-10E

100mV

40mA

550mV

DCS 150-7E

150mV

20mA

825mV

DCS 300-3.5E

300mV

15mA

1650mV

DCS 600-1.7E

600mV

6.8mA

3300mV

Output
DCS Series 1 kW

Output Power

Voltage VDC

Current ADC @ 50°C

DCS 8-125E

0-8

0-125

DCS 10-100E

0-10

0-100

DCS 20-50E

0-20

0-50

DCS 33-33E

0-33

0-33

DCS 40-25E

0-40

0-25

DCS 50-20E

0-50

0-20

DCS 60-18E

0-60

0-18

DCS 80-13E

0-80

0-13

DCS 100-10E

0-100

0-10

DCS 150-7E

0-150

0-7

DCS 300-3.5E

0-300

0-3.5

DCS 600-1.7E

0-600

0-1.7

Output
DCS Series 1 kW

Constant Voltage Mode*

Ripple** (rms) mV

Noise** (p-p) mV

Transient Response
time μs (typ)

DCS 8-125E

4

60

500

DCS 10-100E

4

60

500

DCS 20-50E

4

60

500

DCS 33-33E

4

60

500

DCS 40-25E

4

60

500

DCS 50-20E

4

60

500

DCS 60-18E

4

60

500

DCS 80-13E

4

60

500

DCS 100-10E

4

60

500

DCS 150-7E

12

160

500

DCS 300-3.5E

20

200

500

DCS 600-1.7E

50

300

500

Output
DCS Series 1 kW

Combined Regulation Line and Load %

Temp Co-efficient Voltage %

Voltage Drift
% Vmax (typ)

DCS 8-125E

0.2

0.02

0.05

DCS 10-100E

0.2

0.02

0.05

DCS 20-50E

0.2

0.02

0.05

DCS 33-33E

0.2

0.02

0.05

DCS 40-25E

0.2

0.02

0.05

DCS 50-20E

0.2

0.02

0.05

DCS 60-18E

0.2

0.02

0.05

DCS 80-13E

0.2

0.02

0.05

DCS 100-10E

0.2

0.02

0.05

DCS 150-7E

0.2

0.02

0.05

DCS 300-3.5E

0.2

0.02

0.05

DCS 600-1.7E

0.2

0.02

0.05

Output
DCS Series 1 kW

Constant Current Mode*

Regulation line and load % combined

Ripple (rms)** mA

DCS 8-125E

0.2

160

DCS 10-100E

0.2

128

DCS 20-50E

0.2

25

DCS 33-33E

0.2

10

DCS 40-25E

0.2

7

DCS 50-20E

0.2

7

DCS 60-18E

0.2

6

DCS 80-13E

0.2

4

DCS 100-10E

0.2

3

DCS 150-7E

0.2

2

DCS 300-3.5E

0.2

1

DCS 600-1.7E

0.2

1

Output
DCS Series 1 kW

Input Current, A Nominal

Efficiency % (Typ.)

230V Single Phase

208V Three Phase

DCS 8-125E

8

N/A

82

DCS 10-100E

8

N/A

82

DCS 20-50E

8

N/A

82

DCS 33-33E

8

N/A

84

DCS 40-25E

8

N/A

84

DCS 50-20E

8

N/A

84

DCS 60-18E

8

N/A

86

DCS 80-13E

8

N/A

86

DCS 100-10E

8

N/A

86

DCS 150-7E

8

N/A

86

DCS 300-3.5E

8

N/A

86

DCS 600-1.7E

9.5

N/A

86

Stay informed

To keep you in the loop of our latest news, register now for our email newsletter.