Sorensen DCS 40-75E Programmable DC Power Supply 40V 75A 3000W

Description

Sorensen DCS 40-75E Programmable DC Power Supply 40V 75A 3000W is ideally suited for a wide range of applications requiring DC power in a small form factor. Applications range from manufacturing test and burn-in of automotive components, avionics electronics, telecommunications and consumer products to beam steering, process control and laboratory R&D use.

The DCS Family of 1 kW, 1.2 kW and 3 kW programmable power supplies utilizes unique packaging techniques to achieve continuous full output power (1 kW, 1.2 kW or 3 kW) in any volt/amp combination within the rated output voltage and current limits in a low profile chassis, Demonstrated large installed base over a long period of time, the DCS family provides a highly reliable power platform.

This family has an easy-to-use front panel with 10-turn potentiometers to adjust voltage and current settings that are displayed simultaneously. LEDs indicate overtemperature, remote programming, shutdown and over voltage protection, status and constant-voltage/current mode operation. The DCS 3 kW Models have push button control of the output standby mode, OVP reset, remote/local programming and preview status of voltage, current and OVP setpoints.

The DCS family can also be controlled remotely. Four analog control modes are standard as well as isolated analog control (option). Computer control can be accomplished over IEEE488.2 GPIB (option) or LXI-compliant Ethernet (option).

Features

  • High power density / low ripple and noise
  • High programming resolution with Ethernet interface
  • Constant voltage and current mode
  • Remote sensing
  • Isolated analog control and monitoring (optional)
Download Data Sheet
Print
Email

Specifications

Common
Meter Accuracy 1% of full scale + 1 count
Max. Voltage Differential from Output to Safety Ground 150 VDC
Remote Start/Stop and Interlock TTL compatible input or 12-250 VAC (12-130 VDC) or a contact closure
Cooling Internal fan, over temperature shutdown if internal heat sink exceeds set temperature
Remote Sense The maximum allowed sense line drop is 4V per line (2V on the DCS 8/10V 1 kW/1.2 kW models and 1V/line for all 3 kW models). Line drop subtracts from the maximum available output voltage at full rated power.
Remote Programming Enabled via external jumper on rear panel connector J3
Overvoltage Protection Crowbar type adjustable from 5-110% of rated output using front panel control (local or remote program selectable via J3 jumper)
Remote Analog Programming Linearity ±1% Accuracy: ±5%
Regulatory Certified to UL/CSA 61010 and IEC/EN 61010-1 CE Compliant (LVD and EMC directive)
Input: Voltage and Frequency
Output Power

200 – 250 VAC

190 – 250 VAC

3 kW

single phase, 20A typical, 47- 63 Hz

three phase, 14A 47-63 Hz

Output: Voltage and Current
3kW Model

Voltage

Current

DCS 8-350E

0 – 8

0 – 350

DCS 12-250E

0 – 12

0 – 250

DCS 20-150E

0 – 20

0 – 150

DCS 40-75E

0 – 40

0 – 75

DCS 55-55E

0 – 55

0 – 55

DCS 60-50E

0 – 60

0 – 50

DCS 80-37E

0 – 80

0 – 37

DCS 150-20E

0 – 150

0 – 20

Output
Voltage Resolution 0.02%
Ripple (mV rms or p-p) See table
Regulation Line For input voltage variation over the AC input voltage range, with constant rated load.
Load For 0-100% load variation, with constant nominal line voltage.
Voltage 0.1%
Current 0.1%
Transient Response Typically recovers in 500 μs (1 & 1.2 kW) or 1ms (3k W) to 1% of steady-state output voltage (within 1% of Vmax) for 70-100% or 100-70% load change.
Stability ±0.05% of maximum voltage or current over 8 hours after 30 minute warm-up time at fixed line, load and temperature
Efficiency See table below Temperature Coefficient: 0.02%/°C of maximum output voltage; 0.03%/°C of maximum output current. Change in output per °C change in ambient temperature, with constant line and load
Physical
Dimensions Width: 19” (482 mm) W, Depth 17.52” (445 mm)

Height:  2U or 3.46” (87mm)

Weight & Shipping Weight
Weight 33 lbs. (15 kg)
Shipping Weight 42 lbs. (19 kg)
Environmental
Operating Temperature 0°C to 50°C (no derating)
Storage Temperature -55°C to 85°C
Humidity Range 0 to 80% RH, non condensing
Programming Specifications
DCS Series 3 kW

Programming Accuracy M130/M131/M9C/M85 Options

Voltage 0.1% +

Current 0.1% +

OVP 0.5% +

DCS 8-350E

8mV

1400mA

44mV

DCS 12-250E

12mV

1000mA

66mV

DCS 20-150E

20mV

600mA

110mV

DCS 40-75E

40mV

300mA

220mV

DCS 55-55E

55mV

220mA

303mV

DCS 60-50E

60mV

200mA

330mV

DCS 80-37E

80mV

148mA

440mV

DCS 150-20E

150mV

80mA

825mV

Output
DCS Series 3 kW

Output Power

Voltage VDC

Current ADC @ 50°C

DCS 8-350E

0-8

0-350

DCS 12-250E

0-12

0-250

DCS 20-150E

0-20

0-150

DCS 40-75E

0-40

0-75

DCS 55-55E

0-55

0-55

DCS 60-50E

0-60

0-50

DCS 80-37E

0-80

0-37

DCS 150-20E

0-150

0-20

Output
DCS Series 3 kW

Constant Voltage Mode*

Ripple (rms) ** mV

Noise (p-p) mV

Transient Response
time μs (typ)

DCS 8-350E

15

100

1000

DCS 12-250E

10

100

1000

DCS 20-150E

10

100

1000

DCS 40-75E

20

100

1000

DCS 55-55E

20

100

1000

DCS 60-50E

20

100

1000

DCS 80-37E

20

100

1000

DCS 150-20E

30

200

1000

Output
DCS Series 3 kW

Constant Voltage Mode*

Ripple (rms) ** mV

Noise (p-p) mV

Transient Response
time μs (typ)

DCS 8-350E

15

100

1000

DCS 12-250E

10

100

1000

DCS 20-150E

10

100

1000

DCS 40-75E

20

100

1000

DCS 55-55E

20

100

1000

DCS 60-50E

20

100

1000

DCS 80-37E

20

100

1000

DCS 150-20E

30

200

1000

Output
DCS Series 3 kW

Constant Current Mode*

Regulation line and load % combined

Ripple (rms)** mA

DCS 8-350E

0.2

DCS 12-250E

0.2

DCS 20-150E

0.2

DCS 40-75E

0.2

DCS 55-55E

0.2

DCS 60-50E

0.2

DCS 80-37E

0.2

DCS 150-20E

0.2

Output
DCS Series 3 kW

Input Current, A Nominal

Efficiency % (Typ.)

230V Single Phase

208V Three Phase

DCS 8-350E

24

13

82

DCS 12-250E

26

14

82

DCS 20-150E

26

14

82

DCS 40-75E

26

14

86

DCS 55-55E

26

14

82

DCS 60-50E

26

14

86

DCS 80-37E

26

14

86

DCS 150-20E

26

14

86

* Typical resolution is 0.02% ** rms ripple typical from 20 Hz to 300 kHz