Sorensen SFA 160-94 High Power Current Source 160V 94A 15kW
Description
Sorensen SFA 160-94 High Power Current Source 160V 94A 15kW builds on the industry leading Sorensen SGA series to provide a high power current source for laser diode applications. State of the art high power laser diodes require well-regulated current control to avoid catastrophic damage. Under anomalous operating conditions, excessive stored energy in the output circuit of the power supply can result in peak stresses that can permanently damage the device. Providing a constant current regulation mode only, the SFA’s low stored energy output minimizes damage potential for sensitive devices as well as enabling a current slew rate of up to 400 A/msec.
Features
- High Power Density: Up to 15 kW in a 3U / 30 kW in a 6U chassis
- Wide Voltage Range: 0-40V up to 0-600V, in increments of 5 kW from 5 to 30 kW
- Fast Load Transient Response: Protection from undesired voltage excursions
- Low RMS and P-P Noise: Suitable for the most sensitive applications
- Parallelable up to 150 kW: Expandable as your requirement grows
- Modular Design: Upgradeable for the ultimate in investment protection
- Sequencing: Program custom waveforms
- Easy-to-read Fluorescent Display: SGI supports English, French, German, Italian, Spanish, Chinese, Japanese, and Korean languages
- 16-bit Resolution: Optional IEEE-488.2 + RS-232C + Ethernet provides precise control
- Ethernet Control: LXI Class C compliant communication through integrated web server
- Direct Relay Control: Control output and sense isolation relays, along with polarity relays. (Ethernet Option Only)
- Hardware Trigger: Ethernet Option Only
- 5 Year Warranty
Sorensen SFA 160-94 Applications
- Process Control
- Product Development
- Research
- Automotive Component Test
- Rackmount ATE Systems
- Battery Charging
Specifications
Ratings | ||||||
Voltage |
5kW |
10kW |
15kW |
20kW |
25kW |
30kW |
0 – 60V |
0-83A |
0-167A |
0-250A |
0-333A |
0-417A |
0-500A |
0 – 100V |
0-50A |
0-100A |
0-150A |
0-200A |
0-250A |
0-300A |
0 – 160V |
0-31A |
0-63A |
0-94A |
0-125A |
0-156A |
0-188A |
Electrical Characteristics | ||||||
Control Mode | Current Control | |||||
Front Panel Meter Accuracy | Voltage ±0.5% of full-scale + 1 digit Current ±0.5% of full-scale + 1 digit |
|||||
Load Regulation | (no load to full load, nominal AC input) Current 0.1% of rated output current | |||||
Line Regulation | (±10% of nominal AC input) Current 0.05% of rated output current | |||||
Current Ripple | 1% p-p of full-scale current | |||||
Transient Response | Output current recovers to within 1% of current setpoint within 1ms for a 10 to 100% or 100% to 10% step load change | |||||
Output Slew Rate (10-90% resistive load) | 250A/ms (400A/ms typical) rise, 200A/ms typical fall; 160V model 87A/ms/5kW (145A/ms/5kW typical), 60A/ms, typical, fall | |||||
Output Capacitance | 60V Models: <2µF 160V Models: <3µF |
|||||
Stability | ±0.05% of setpoint after 8–hr. warm-up at fixed line, load, and temperature using remote sense | |||||
Power Factor | >0.9 typical for 208/220VAC input >0.78 typical for 380/400VAC input >0.7 typical for 440/480VAC input |
|||||
Remote Analog Control | Current Setpoint Accuracy ±0.8% of full-scale output ● Overcurrent Protection ±1% of full-scale output ● Resistive Control 0–5 kW = 0-100% Current ● Voltage Control 0–5 or 0–10 VDC = 0-100% Current ● Overcurrent Protection 0–5.5 VDC = 0-110% |
|||||
Efficiency | 87% typical at full load, nominal line | |||||
Remote Control/Monitor | On/Off control via contact closure, 6-120 VDC or 12-240VAC, and TTL or CMOS switch, current monitor, OCP limit set, summary fault status | |||||
Overvoltage Protection | Fixed at approximately 110% of the rating compliance voltage. Reset requires cycling the front panel standby power switch off/on Isolated Analog Control (option) Input to Output Isolation: 500 V Compliant with maximum terminal float voltage. Recommended operation under SELV normal conditions. |
|||||
Environmental Characteristics | ||||||
Ambient Operating Temperature | 0 to 50°C | |||||
Storage Temperature | -25 to 65°C | |||||
Temperature Coefficient | Current Setpoint 0.03% / °C of rated current | |||||
Cooling | Internal Fans. Zero clearance stacking | |||||
Humidity | 0 to 90% at 40°C; 0 to 50% at 25°C non-condensing | |||||
Altitude | Full power at 5,000 feet, 10% derating of full power for every 1,000 feet above 5,000 feet | |||||
Regulatory | Certified to UL/CSA 61010 and IEC/EN 61010-1 CE Compliant (LVD and EMC Directives) | |||||
Input Power Options | ||||||
Configuration | 3–phase, 3–wire plus ground. Not phase rotation sensitive. Neutral not used | |||||
Voltage Selection | 208/220 VAC±10%, 47 to 63 Hz 380/400 VAC±10%, 47 to 63 Hz 440/480 VAC±10%, 47 to 63 Hz |
|||||
Physical | ||||||
Up to 15kW in 3U | 19.00in W x 25.12in D x 5.25inH; 80 lbs. (48.3cm W x 63.8cm D x 13.3cm H; 36 kg) | |||||
15 – 30kW in 6U | 19.00in W x 25.12in Dx 10.5in x H; 160 lbs. (48.3cm W x 63.8cm D x 36.7cm H; 73 kg) |