Sorensen SGI Series Modular Programmable DC Power Supply 5kW – 30kW

Description

Sorensen SGI Series Modular Programmable DC Power Supply 5kW – 30kW represents the next generation of high power programmable DC power supplies. The SG Series is designed for exceptional load transient response, low noise and the highest power density in the industry. With a full 15 kW available down to 20Vdc output, and 12kW at 10Vdc and 1200ADC in a 3U package, the SG leads the industry in power density. The SG provides models up to 1000Vdc at 15amps. The power density is enhanced by a stylish front air intake allowing supplies to be stacked without any required clearance between units.

At the heart of the SG series is a 5 kW power module. Depending on the output voltage, one to six modules can be configured in a single chassis to deliver 5 kW to 30 kW of power. Combinations of these chassis can then be easily paralleled to achieve power levels up to 150 kW. Paralleled units operate like one single supply providing total system current. Available in two control versions, the SGA has basic analog controls, while the SGI provides intelligent control features.

(Sorensen General purpose Analog) The SGA, with its industry leading price performance, is available for customers requiring simple front panel analog controls or external control. With the same high performance power electronics as the SGI, the SGA provides essential features like 10- turn potentiometers for setting voltage and current, 3 ½ digits LED readout plus front panel over-voltage protection (OVP) preview/adjustment and reset.

Features

  • High Power Density: up to 15 kW in 3U, 30 kW in a 6U chassis
  • Wide Voltage Range: 0-10V up to 0-1000V, from 4 to 30 kW
  • Fast Load Transient Response: Protection from undesired voltage excursions
  • Low Ripple and Noise
  • Hardware Trigger (Ethernet Option)
  • Parallelable up to 150 kW
  • Sequencing: Free system controller & speed up test
  • Low audible noise: Temperature controlled variable speed fans

Sorensen SGI Applications

  • Burn-In
  • Materials Research
  • Product Validation
  • Rackmount ATE Systems
  • Compliance Testing
  • Process Control
  • Automotive Electronics
  • Battery Charging
Download Data Sheet
Print
Email

Specifications

SGI / SGA Comparison Chart
Feature

SGA

SGI

Modular Design

Fast Load Transient

Parallelable

Analog & Digital Summing

Optional

Direct Front Panel V/1 Control

3½ Digit LED Readout

Graphics Display

Sequencing

Save / Recall Setups

System Power Readouts

Constant Power Mode

IEEE-488.2/RS-232C

Optional

RS-232C Std
IEEE-488.2 Optional

LXI Class C Ethernet/ RS-232

Optional

RS-232C Std, Ethernet Optional

Front Panel Dust Filter

Optional (3U unit only)

Optional (3U unit only)

Common
Remote Sense Terminals are provided to sense output voltage at point of load. Maximum line drop 5% of rated voltage per line for 40-100V models, line drop 1V of rated voltage per line for 10-20V models, 1.5V for 30V models, 2% of rated voltage per line for models 160V and greater. (Greater line drop is allowed, but output regulation specifications no longer apply).
Parallel Operation Up to 5 units may be paralleled for additional current within the power supply single-unit specifications, with exception of the DC output current set accuracy. Additional paralleled SG units will add 0.3% inaccuracy per unit. To parallel more than 5 units, contact factory.
Series Operation Up to 2 units (see Output Float Voltage)
Input
Nominal Voltage
3 phase, 3 wire + ground
208/220 VAC (operating range 187 – 242 VAC)
380/400 VAC (operating range 342 – 440 VAC)
440/480 VAC (operating range 396 – 528 VAC)
Frequency 47 – 63Hz , 400Hz ( 400Hz @ 208VAC, for 6U units is optional modification and does not carry CE, UL or CSA markings )
Power Factor >0.9 typical for 10V – 30V, 50V, 1000V and other models with optional “PF” modification.
>0.75 typical for 208/220 VAC input
(40V, 60V – 800V models, 0.9 available with modification “PF”)
>0.72 typical for 380/480 VAC input
(40V, 60V – 800V models, 0.9 available with modification “PF”)
>0.69 typical for 440/480 VAC input
(40V, 60V – 800V models, 0.9 available with modification “PF”)
Protection ½ cycle ride-though , typical, on all three phases, 3 cycle ride through on single phase; missing phase shutdown ( 800V model 6.4 msec on all 3 phases )

SORENSEN SG Series

Power

Unit Weight:

5kW

52 lbs.

10kW

66 lbs.

15kW

80 lbs.

20kW

132 lbs.

25kW

146 lbs.

30kW

160 lbs.

Shipping Weight

62 lbs

76 lbs.

115 lbs.

167 lbs.

181 lbs.

195 lbs.

Dimensions: L/W/H

26.4″ x 19″ x 5.25″

26.4″ x 19″ x 5.25″

26.4″ x 19 x 5.25″

25″ x 19″ x 10.5″

25″ x 19″ x 10.5″

25″ x 19″ x 10.5″

(40V and above)

Voltage-Current Combinations:

(rounded to whole A)

40X125

40X250

40X375

**

**

**

50X100

50X200

50X300

**

**

**

60X83*

60X167*

60X250*

60-333*

60-417*

60-500*

80X63

80X125

80X188

80-250

80-313

80-375

100X50*

100X100*

100X150*

100-200*

100-250*

100-300*

160X31*

160X63*

160X94*

160-125*

160-156*

160-188*

200X25

200X50

200X75

200-100

200-125

200-150

250X20

250X40

250X60

250-80

250-100

250-120

330X15

330X30

330X45

330-61

330-76

330-91

400X12

400X25

400X38

400-50

400-63

400-75

600X8

600X17

600X25

600-33

600-42

600-50

800X6

800X13

800X19

**

**

**

SORENSEN SG Series

Power

Unit Weight:

4kW

65 lbs.

5kW

65 lbs.

8kW

85 lbs.

10kW

85 lbs.

12kW

110 lbs.

15kW

110 lbs.

Shipping Weight

85 lbs

85 lbs

105 lbs.

105 lbs.

130 lbs.

130 lbs.

Dimensions: L/W/H

26.5″ x 19″ x 5.25″

26.5″ x 19″ x 5.25″

26.5″ x 19″ x 5.25″

26.5″ x 19″ x 5.25″

26.5″ x 19″ x 5.25″

26.5″ x 19″ x 5.25″

(30V and below)

Voltage-Current Combinations:

10X400

10X800

10X1k2 (1200)

15X267

15X534

15X801

20X250

20X500

20X750

30X167

30X334

30X501

Environmental
Operating Temperature 0 to 50º C
Storage Temperature -25º C to 65º C
Humidity Range Relative humidity up to 95% non-condensing, 0º C – 50º C
Altitude Operating full power available up to 5,000 ft. (~1,500 m), derate 10% of full power for every 1,000 feet higher; non-operating to 40,000 ft. (~12,000 m)
Cooling Front and side air inlet, rear exhaust. Temperature controlled, variable speed fans. Units may be stacked without spacing.
Regulatory Certified to UL/CSA 61010 and IEC/EN 61010-1 by a NRTL, CE Compliant, Semi-F47 Compliant.
LVD Categories: Installation Category II: Pollution Degree 2; Class II Equipment: for Indoor Use Only, back panel not user accessible
(see user manual for installation instructions)
EMC Directive, EN 61326:1998
Front Panel Dust Filter 30 PPI (Pores Per Inch) – must ensure adequate airflow and / or derate max. temperature.
3U unit only.
Output
Ripple & Noise (Voltage Mode, Typical) See Output: Voltage & Current Ranges Chart above. Ripple and noise specified at full load, nominal AC input. Noise measured with 6ft. cable, 1μf at load
Ripple (Current Mode) <+/- 0.04% of full scale rms current
DC Voltage Slew Rate (40-800V) ≈< 100 ms 5-95% of full scale typical – resistive load (Contact factory for model specific slew rates)
Output Voltage Rise Time
(10-30V)

Rise Time, ms, MAX

Condition

10

Measured from 10% to 90% of the output voltage change – resistive load, typical

Output Voltage Fall Time
(10-30V)

Fall Time, MS MAX

Condition

No Load 1
50

100% CC Load 10

100% CR Load 10

Measured from 90% to 10% of the output voltage change. – resistive load, typical

Output Current Rise Time
(10-30V)

Rise Time, ms, MAX

Condition

20

Measured from 10% to 90% of the output current change – resistive load, typical

Output Current Fall Time
(10-30V)

Rise Time, ms, MAX

Condition

10

Measured from 90% to 10% of the output current change – resistive load, typical

DC Current Slew Rate 45A / ms typical – resistive load
Line Regulation (with sense wires used) (±10% of nominal AC input, constant load)
Voltage Mode: +/- 0.01% of full scale (40-800V)
Current Mode: +/- 0.05% of full scale (40-800V)
Voltage Mode and Current Mode: +/- 0.05% of full scale (10-30V)
Load Regulation (with sense wires used) (no load to full load, nominal AC input)
Voltage Mode: +/- 0.02% of full scale (40-800V)
Current Mode: +/- 0.1% of full scale
Voltage Mode: +/- 0.05% of full scale (10-30V)
Load Transient Response Recovers within 1ms to +/-0.75% of full-scale of steadystate output for a 50% to 100% or 100% to 50% load change
Efficiency 87% typical at nominal line and max load
Stability ±0.05% of set point after 30 minute warm-up and over 8 hours at fixed line, load and temperature, typical
Temperature Coefficient 0.02%/ C of maximum output voltage rating for voltage set point, typical
0.03%/ C of maximum output current rating for current set point, typical
Output Float Voltage Negative terminal within +/- 300 V of chassis potential.
(We recommend the use of optional isolated analog Interface (IAI).) Supplies in “series” should be the same output voltage/current, in not system current is limited to lower of the two supplies.