LeCroy WAVEJET 322A 2 Channel 200 MHz Oscilloscope 1 GSa/s
Description
The WaveJet 300A series provides the banner specifications, feature set and user interface to simplify how you work and shorten debug time. With a big, bright 7.5″ display, long 500 kpts/Ch memory and up to 2 GS/s you will easily capture and see every detail of your waveform. The USB ports provide a quick way to save waveforms; store or print screen captures or connect to a PC. Math and measurement tools help you understand the waveforms and Replay mode allows you to look at a history of what has been captured. Altogether these specs, features and capabilities make the WaveJet 300A the right oscilloscope for your debugging needs.
Features
- 200 MHz bandwidth
- 2 channels
- Sample rates up to 2 GS/s
- Long waveform memory
- 500 kpts/Ch
- 26 measurement parameters
- Replay history mode
- 7.5″ color display
- Multi-language user-interface and help
- USB Host and Device connections for printers, memory sticks and PC remote control
- Available GPIB and LAN connectivity
Specifications
Main Specifications |
312A |
314A |
322A |
324A |
332A |
334A |
352A |
354A |
Bandwidth |
100 MHz |
200 MHz |
350 MHz |
500 MHz |
||||
Rise Time |
3.5 ns |
1.75 ns |
1 ns |
750 ps |
||||
Input Channels |
2 |
4 |
2 |
4 |
2 |
4 |
2 |
4 |
Display |
7.5″ Color flat-panel TFT-LCD, 640 x 480 VGA |
|||||||
Sample Rate |
1 GS/s |
2 GS/s (Interleaved), 1 GS/s (all channel) |
||||||
Sample Rate |
100 GS/s |
|||||||
Peak Detect Period |
1 ns |
|||||||
Memory Length |
500 kpts/Ch (all channels) |
|||||||
Capture Time |
500 µs at 1 GS/s, 250 µs at 2 GS/s |
|||||||
Vertical Resolution |
8 bits |
|||||||
Vertical Sensitivity |
2 mV/div – 10 V/div |
2 mV/div – 10 V/div, 2 mV/div – 2 V/div (50 Ω) |
||||||
Vertical (DC Gain) Accuracy |
±(1.5% + 0.5% of full scale) |
|||||||
BW Limiting Filters |
20 MHz |
20 MHz, 200 MHz |
||||||
Maximum Input Voltage |
400 V CAT I |
400 V CAT I, 5 Vrms (50 Ω) |
||||||
Input Coupling |
GND, DC 1 MΩ, AC 1 MΩ |
GND, DC 1 MΩ, AC 1 MΩ, DC 50 Ω |
||||||
Input Impedance |
1 MΩ ±1.5% || 20 pF |
1 MΩ ±1.5% || 16 pF, 50 Ω ± 1.5% |
||||||
Probing System |
BNC with Probe Sense Ring |
|||||||
Probes |
PP010 (One per Channel) |
PP006A (One per Channel) |
||||||
Timebase Range |
5 ns/div – 50 s/div |
2 ns/div – 50 s/div |
1 ns/div – 50 s/div |
500 ps/div – 50 s/div |
||||
Roll Mode |
50 ms/div – 50 s/div (100 kS/s maximum) |
|||||||
Timebase Accuracy |
10 ppm (typical) |
|||||||
Triggering |
||||||||
Triggers |
Edge, Width, Period, Pulse Count, TV |
|||||||
Measure, Zoom, Math, and Replay |
||||||||
Measure |
Base, Cycle Mean, Cycle RMS, Duty Cycle, Fall Time (90-10%), Fall Time (80-20%), Frequency, Integral, Maximum, Mean, Minimum, Number of +Pulses, Number of -Pulses, +Overshoot, -Overshoot, Peak-Peak, Period, +Pulse Width, -Pulse Width, Rise Time (20-80%), Rise Time (10-90%), RMS, Skew, Skew@level, Top, Top-Base |
|||||||
Zoom |
Use front panel QuickZoom button to zoom all waveforms in a seperate zoom grid |
|||||||
Math |
Operators include Sum, Difference, Product, and FFT (up to 8 kpts with Rectangular, Hanning, or Flat Top) |
|||||||
Replay |
Look back at the history of waveform acquisitions (Maximum 1024 acquisitions) |
|||||||
Physical Dimensions |
||||||||
Dimensions |
190 mm (H) x 285 mm (W) x 102 mm (D) |
|||||||
Net Weight |
3.2 kg; 7 lbs |