Tenney ETCU Solar Panel Test Chamber -60°C to 200°C

Description

ETCU Series Solar Panel Testing Environmental Test Chambers The ETCU series was designed specifically for solar panel testing and features integrated options to provide reliability, quiet operation, and proven performance for your testing requirements. The ETCU series uses the latest in HFC environmentally friendly refrigerants, which generate much lower compressor temperatures. Construction All models feature vapor-tight, continuously welded stainless steel interiors. Structural reinforcement is used at all critical points. Through-wall ports are continuously welded. A combination of fiberglass and polyurethane insulation surrounds the chamber to maximize insulating characteristics, thus ensuring minimal thermal transfer.

 

Features

  • Large chamber space tailored to standard solar panel sizes
  • Vapor-tight, continuously welded stainless steel interiors
  • Structural reinforcement at all critical points
  • Through-wall ports continuously welded
  • Fiberglass and polyurethane insulation 
  • Low-mass nichrome, open wire heating elements
  • Automatic humidity vent
  • Panel mounting clips
  • Platinum RTD sensor for temperature measurement
  • Electronic, capacitive sensor for humidity measurement
  • VaporFlo II
  • Vertical-down recirculating conditioning stream
  • Double gasket doors

Meets the following standards:

  • UL 1703—35, 36
  • IEC 60068—2.7B
  • IEC 61215—10.11, 10.12, 19.13
  • IEC 61646—10.13
  • IEC 62108—10.6, 10.7, 10.8
  • ASTM E1171-04—6.5, 6.6, 6.7

Controller – VersaTenn V

  • Two channel controller
  • Auto/ manual control
  • Pentium class processor
  • 8 MB flash disk on chip storage
  • USB flash disk port
  • RS-232 communications
  • Color LCD touch screen interface with real-time graphic displays
  • Microsoft Windows CE Operating System
  • Logic circuits automatically select cooling and heating modes
  • Near infinite number of programs and steps possible
  • RTD sensors for temperature measurement
  • 2 process inputs, 10 temperature control outputs, 6 event outputs
  • Alarm output for each channel
  • RS232 data communication
Print
Email

Specifications

 

ETCU 110
Environmental Test Chamber for Solar Panel Testing

ETCU 132
Environmental Test Chamber for Solar Panel Testing

Temperature Range

-60°C to +200°C

-60°C to +200°C

Humidity Range

20% to 98% in the dry bulb temperature range of 20°C to 85°C limited by a 3°C dew point 20% to 98% in the dry bulb temperature range of 20°C to 85°C limited by a 3°C dew point

20% to 98% in the dry bulb temperature range of 20°C to 85°C limited by a 3°C dewpoint

Interior Dimensions
W x D x H in. (cm)

40 x 79 x 60 (101.6 x 200.7 x 152.4)

48 x 79 x 60 (121.9 x 200.7 x 152.4)

Exterior Dimensions
W x L x H in. (cm)

65.5 x 119 x 112 (166.4 x 302.3 x 284.5)

75.5 x 119 x 112 (191.8 x 302.3 x 284.5)

Standard Voltage

460V 3 Phase 60 Hz.

460V 3 Phase 60 Hz.

Cabinet Type

Floor Model

Floor Model

Stay informed