Tenney T2 Temperature Humidity Cycling Chamber -75°C to 200°C
Description
T2 Series – Wide Range, Small Footprint The Tenney T2 temperature and humidity cycling chamber simulates a wide range of temperature and humidity conditions while utilizing minimal floor space. We specifically designed these environmental chambers to have a compact exterior and an ample interior workspace. The T2 Temperature and Humidity Cycling Chamber design allocates space within the interior of the cabinet for all standard options. This greatly improves the mobility of the unit as well as the overall appearance.
Features
- Vapor-tight, continuously welded stainless steel interiors
- Low workspace height to ease the loading and unloading of product
- Vertical recirculation conditioning system
- EIA-232 and EIA-485 data communications with Modbus RTU protocol
- Platinum Resistance Temperature Detector (RTD)
- Electronic capacitive sensor
- Chamber overtemperature protection
- Cascade refrigeration system
- Built in safety devices
- Explosion relief
Performance
- Temperature Range: -75°C to +200°C
- Humidity capability: 20% to 95% RH in the dry bulb range of +20°C to 85°C as limited by a 3°C dewpoint. Test data based on 24°C ambient, sea level, 60Hz.
- On 50 Hz or higher than 24°C ambient, performance may be reduced. Consult factory regarding any special cooling requirements. CFC-free refrigerants are used exclusively on all Tenney chambers.
Controller – VersaTenn III Controller
- Two Channel
- Profiling: 10 Profiles, 99 Steps Max.
- Automatic & Manual Control
- 2 Process Inputs: 100 Ohm Platinum RTD Sensor for each chamber
- 1 Event Input
- 10 Temp. Control Outputs: Time Proportioned and On / Off Control
- Alarm Output
- Guaranteed Soak
Specifications
Model |
T2RC |
T2C |
||
Workspace |
W |
16(406) |
16(406) |
|
D |
13(330) |
13(330) |
||
H |
15(381) |
15(381) |
||
Exterior |
W |
26(660) |
27(686) |
|
D |
26(660) |
27(686) |
||
H |
67(1702) |
65(1651) |
||
Temperature |
T2RC |
T2C |
||
Low |
C |
-75 |
-75 |
|
High |
C |
+200 |
+200 |
|
Humidity capability |
20% to 95% RH in the dry bulb range of +20°C to 85°C as limited by a 3°C dewpoint. |
Note: Test data based on 24°C ambient, sea level, 60Hz. On 50 Hz or higher than 24°C ambient, performance may be reduced. Consult factory regarding any special cooling requirements. CFC-free refrigerants are used exclusively on all Tenney chambers.
Change Rates in Minutes |
|||
Ambient to C Chamber Empty |
200°C |
90 Minutes |
|
150°C |
40 Minutes |
||
100°C |
25 Minutes |
||
93°C |
17 Minutes |
||
65°C |
9 Minutes |
||
2°C |
5 Minutes |
||
-7°C |
7 Minutes |
||
-12°C |
10 Minutes |
||
-40°C |
30 Minutes |
||
-54°C |
45 Minutes |
||
-65°C |
70 Minutes |
||
-73°C |
100 Minutes |
||
-75°C |
Ultimate |
||
Utilities, etc |
|||
Refrigeration |
(2) 1/2) HP+ 1/2 HP |
(2) 1/2) HP + 1/2 HP |
|
Heater Capacity |
500W |
500W |
|
Humidifier
|
W |
500 |
— |
GPH |
0.15 |
— |
|
AMPS @ 115V. 1Ph |
18 |
18 |
|
AMPS Fuse |
20 |
20 |
|
Unit Weight |
LBS/KG |
350/158 |
350/158 |