Teseq CBA 230M-080 Broadband Amplifier 150 kHz – 230 MHz 80W
Description
Teseq CBA 230M-080 Broadband Amplifier 150 kHz – 230 MHz 80W is designed specifically for Conducted EMC testing.
This mismatch tolerant Class A amplifier is ideally suited to provide power into Bulk Current Injection (BCI) Probes, injection clamps and CDN for IEC 61000-4-6 conducted susceptibility testing up to and beyond the normal 10 V emf test level.
The unit is powered from a switched mode power supply for high efficiency, high power factor and wide voltage range operation. The unit is air-cooled with integral fans, and is protected against faulty cooling by excess temperature sensing. Front panel indicators are provided to indicate over-temperature.
Features
- Class A linear and low distortion design
- Ideal for IEC 61000-4-6 testing
- Mismatch tolerant and unconditionally stable
- Rugged design for EMC testing
Specifications
Parameter | Value |
Frequency range (instantaneous) | 0.15 to 230 MHz |
Rated output power | 80 W minimum (90 W typical) |
Output power at 1 dB gain compression | 70 W minimum (80 W typical) |
Gain | 50 dB |
Harmonics at P1 dB | -20 dBc |
Power Supply Voltage | 85-264 VAC |
Power Supply Phases | 1 |