Teseq CDN 117 Coupling/Decoupling Network

Description

Teseq CDN 117 Data Line Coupling/Decoupling Network enables convenient testing with surge pulses of 1.2/50μs on data, signal or peripheral lines, as specified in many product standards. The test method, severity levels, permissible reaction of the EUT and specification of the coupling networks are included in IEC/EN 61000-4-5.

Features

  • Data line surge testing
  • Easy to use bench top housing
  • Conforms to IEC/EN 61000-4-5
  • Complete set includes all
  • accessories
Download Data Sheet
Print
Email

Specifications

Signal line
Max operating voltage AC 250 V

DC 250 V

Max operating current 1.5 A
Ohmic resistance per path <2.5 Ω
Decoupling chokes 1 kHz 20 mH nominal
Pulse 1.2/50 μs pulse
Max pulse voltage 6.6 kV
Series resistor 2 x 40 Ω, 6 W
Coupling adapters INA 170 spark gap device, 90 V trip voltage

INA 171 capacitor 0.1 μF//spark gap device, 90 V trip voltage

INA 174 capacitor 0.5 μF

Stay informed

To keep you in the loop of our latest news, register now for our email newsletter.