LogiMetrics A240/S EMC / TWT Power Amplifier 2 GHz - 4 GHz 10W
Description
The LogiMetrics 3.5″ high A230 series and the 525″ high A240 series of medium power microprocessor based instrumentation and subsystem amplifiers provide the user with proven reliable instrumentation for a wide variety of test and system applications.
The operating modes are selectable via front panel push button controls and the operating mode is displayed on an LED digital display. Additionally, salient power supply voltages, currents and fault indicators can be displayed.
Each amplifier is remote controllable via the standard IEEE-488 GPIB. Each amplifier features complete regulation of the helix, filament, and grid power supplies, thus providing stable operation and long life for the TWTs. The TWT is fully protected against power supply malfunctions such as helix over current.
Features
- Monitor-Digital Display
- Standby
- Faults
- Helix Voltage/Current
- Collector Voltage
- Power Out (option 30) in Watts and
- DBm
- Mode- Digital Display
- Power On/Off
- RF On
- Controls
- Power On
- Power Off
- RF On
- RF Off
- Local Select
- Ease of Maintenance
- Designed to meet the safety requirements of IEC-348 and Underwriters laboratory of American Standards
- Broadband Coverage
LogiMetrics A240/S Applications
EMC Susceptibility Testing |
Threat Simulation |
Communications |
Antenna Patterns Testing |
General laboratory Instrumentation |
Component Testing |
System Preamplifiers |
Specifications
Frequency Range (GHz) |
2–4 GHz |
|||
Min. Pwr Out (Watts) |
10 Watts |
|||
Min. Sat. Gain (dB) |
30 dB |
|||
Max NF (dB) |
35 dB |
|||
Spurious |
-40 dBc (-50 dBc available) |
|||
In/Out Impedance |
50 Ohms |
|||
RF Connectors |
Frequency |
Input |
Output |
|
1-18 GHz |
Type N |
Type N |
||
Location |
Front Panel |
Front Panel |
||
Prime Power |
Switchable 115 or 230 VAC, +-10%, Single Phase, 50-60 Hz, 750 VA max. |
|||
Cooling |
Internal Air Forced |
|||
Air Intake |
Rear Panel |
|||
Air Exhaust |
Rear Panel |
|||
Operating Temperature |
0-50 deg C (40 deg C @ 10,000 Feet) |
|||
Relative Humidity |
95% (non condensing) |
|||
Operating Altitude |
10,000 ft Max. |
|||
Non Operating |
-20 to 70 deg C |
|||
Remote Operation |
Standard operating mode control and status monitoring via IEEE-488 GPIB |
|||
Dimensions |
5.25 x 16.5 x 20.5 in |
|||
Weight |
38 lbs (17.3 kg) |