EM TEST CNI 508N2 Coupling Network Shielded/Unshielded Lines 1 GBit/s

Description

The EM TEST CNI 508N2 is the first coupling/decoupling network available on the market to couple Surge onto shielded and unshielded high-speed communication lines with data rates up to 1,000MBit/s.

Additionally, the CNI 508N2 can be used as a coupling/decoupling network to apply Burst- as well as Ringwave pulses to shielded lines.

The CNI 508 N2 meets the requirements according to the standards IEC 61000-4-5 (Ed. 2.0: 2005) Figure 15 and Figure 16 and the draft IEC 61000-4-5 (Ed. 3.0:2012) Figure 11 and Figure 12.

Features

  • Coupling to unshielded and shielded lines with up to 4 pairs
  • Data transfer up to 1,000MBit/s
  • Residual voltage max. 40V at 3kV
  • Surge test voltage up to 3kV (1.2/50us)
  • Burst test voltage up to 4kV (5/50ns)
  • Ringwave test voltage up to 3kV (0.5us/100kHz)
  • Compatible to PoE and PoE+ requirements
  • DUT/AE connection via RJ45 connectors
Download Data Sheet
Print
Email

Specifications

SURGE TEST MODE
Coupling mode shielded and unshielded cable with up to 4 pairs
Test voltage Max. 3kV* (1.2/50us) (* only with connected RJ45

Connector; if left open the max. test voltage is limited to 1.5kV)

Residual voltage Max. 40V @2kV Surge, line – PE
RINGWAVE TEST MODE
Coupling mode shielded and unshielded cable with up to 4 pairs
Test voltage Max. 3kV* (0.5us/100kHz) (* only with connected RJ45 Connector; if left open the max. test voltage is limited to 1.5kV)
Residual voltage Max. 40V @2kV Ringwave, line – PE
BURST TEST MODE
Coupling mode shielded and unshielded cable with up to 4 pairs
Test voltage Max. 4kV* (5/50ns) (* only with connected RJ45

Connector; if left open the max. test voltage is limited to 1.5kV)

Residual voltage Max. 40V @2kV Burst, line – PE
TELECOM LINE SPECIFICATIONS
Input/output RJ45 female connectors for telecom lines
Terminal layout Pair 1: pins 1/2

Pair 2: pins 3/6

Pair 3: pins 4/5

Pair 4: pins 7/8

Data rate up to 1,000MBit/s
Protection +- 60V between two pairs
Operating voltage Max. 57VDC
Operating current Max. 1A
INPUTS
Surge/Ringwave shield SHV connector
Surge/Ringwave unshielded SHV connector
Burst SHV connector
GENERAL DATA
Dimensions 270mm x 110mm x 140mm (LxWxH)
Weight 6.5kg
Temperature 5°C – 40°C (operation)
Rel. humidity 10% – 90%, non condensing
Stay informed