EM TEST UCS 500N5E Electrical Fast Transient Generator

Description

UCS 500N5E Electrical Fast Transient/Burst Generator up to 5.5 kV as per IEC/EN 61000-4-4

EM TEST UCS 500N5E Electrical Fast Transient/Burst Generator is a fully compliant Burst simulator only as per IEC/EN 61000-4-4 with an extended test voltage range up to 5.5kV. The UCS 500N5E has the best benefit-to-cost ratio and yet it is easily upgradeable to include other test abilities such as Combination Wave Surge and PowerFail.

The UCS 500NE includes a built-in single phase CDN up to 300V/16A AC/DC which can handle all common mains supply voltages. Three-phase CDNs extend its applicability for three-phase testing of DUTs with a nominal current of 100A and more.

USB and GPIB interfaces are provided for remote control via iec.control software. Fail inputs allow controlling an ongoing test sequence based on the status of the DUT.

 

MODEL OVERVIEW

UCS 500N5 Transient Generator for EFT/Burst, Surge & Power Fail up to 5.5 kV as per IEC/EN 61000-4-4. 61000-4-5 and 61000-4-11
UCS 500N5P Power Fail Simulator for Dips & Short Interruptions as per IEC/EN 61000-4-11 and 61000-4-29
UCS 500N5V Combination Wave (Surge only) Generator up to 5kV as per IEC/EN 61000-4-5

Features

  • Fully compliant to IEC 61000-4-4 Am1 Ed.2
  • Test voltage up to 5.5kV
  • Up to 10,000 pulses per second
  • Up to 1,000 pulses per burst
  • Built-in single phase coupler 300V/16A
  • Manual operation from front panel
  • USB and GPIB-Bus for remote control
  • Fail inputs
  • Control of external three-phase couplers
Download Data Sheet
Print
Email

Specifications

TECHNICAL DETAILS
As per EN/IEC 61000-4-4 and EN 61000-6-1, -6-2
Test voltage 200V – 5,500V ± 10%;

100V – 2,750V ± 10% into 50ohm

Pulse shape 5/50ns into 50ohm and 1,000ohm
Rise time tr 5ns ± 30% into 50ohm;

5ns ± 30% into 1,000ohm

Pulse width td 50ns ± 30% into 50ohm;

50ns -15/+100ns into 1,000ohm

Source impedance 50ohm
Polarity Positive/negative
Output
Direct Via 50ohm coaxial connector
Coupling mode L, N, PE; all combinations
DUT supply AC: 300V/16A; 50/60Hz
DC: 300V/16A
CRO trigger 5V trigger signal for oscilloscope
Interface
Serial interface USB
Parallel interface IEEE 488, addresses 1 – 30
Analog output 0 – 10VDC to control an external transformer
CN interface 15pin SubD connector to control an external coupling network
Fail inputs DUT monitoring via Fail1 and Fail2 input (one each)
Dimensions
Dimensions 19″, 3HU
Weight approx. 14kg
Stay informed

To keep you in the loop of our latest news, register now for our email newsletter.