EM TEST Transient Emission Set

Description

EM TEST Transient Emission Set consisting of the BS 200N100 electronic switch, the artificial network AN 200N100 and the BSM 200N40 mechanical switch is an easy-to-use, economic and compact solution, fully compliant to ISO 7637-2.

Small size of the equipment and short interconnections allow to meet the distances specified by the standard. An optional resistor box RS-Box with shunt resistor is available for transient emission measurements as per ISO 7637-2:2004 and ISO 7637-2:2011.

The RS-Box offers the required 40ohm shunt resistor and other demanding shunt resistors values of e.g. 10ohm, 20ohm and 120ohm.

Features

  • BS 200N100 – Electronic switch, 60V DC/100A:
  • – Volt. Drop <1.2V@100A, <0.2V@25A
  • – Peak voltage max. 1,000V
  • – Reverse-polarity/short-circuit protected
  • BSM 200N40 – Mechanical switch, 12/24V DC/40A
  • AN 200N100 – ISO 7637-2, CISPR 25, CISPR 16-1-2
  • – Frequency range 100kHz – 125MHz
  • – 1,000V DC, 250V AC (up to 1kHz)
  • – Current max. 100A AC/DC cont.
  • – Insertion loss < 3dB
Download Data Sheet
Print
Email

Specifications

BS 200N100 – ELECTRONIC SWITCH
SPECIFICATION
Operation voltage Max. 60V DC
Operation current Max. 100A continuous
Peak voltage Max. 1,000V
Inrush current Max. 400A for 200ms
Voltage drop < 1.2V at 100A

< 0.2V at 25A

Overvoltage protection By varistors
Overload protection Short-circuit protected

Reverse-polarity protected

AN 200N100 – ARTIFICIAL NETWORK
TECHNICAL DATA
as per ISO 7637-2, CISPR 25, ISO 11452-4 and CISPR 16-1-2, switchable
Frequency range 0.1 to 125MHz
Operation voltage 1,000V DC/250V AC up to 1kHz
Operation current Max. 100A AC/DC continuous
Inrush current Max. 400A for 200ms
Impedance 5uH // 50ohm for details see datasheet
Insertion loss less than 3dB DUT to receiver output
Inductance 5uH +/-10% air-core coil
Coupling capacitor 0.1uF
BSM 200N40 – MECHANICAL SWITCH
SPECIFICATIONS
Operation voltage DUT supply 12V/24V
Operation current Max. 40A DC continuous, resistive load
Maximum current Imax 40A @13.5V

20A @27.0V

Contact high purity silver contacts, no suppression across relay contact, insulated from the coil circuit