Rohde & Schwarz ESW-series EMI Test Receivers 2 Hz – 44 GHz
Description
Rohde & Schwarz ESW-series EMI Test Receivers 2 Hz – 44 GHz offer outstanding RF characteristics, including high dynamic range and measurement accuracy. It meets the most stringent requirements for certification measurements in line with CISPR, EN, MIL‑STD-461, DO‑160 and FCC. With its FFT-based time domain scan, the R&S®ESW captures and weights disturbance spectra in virtually no time. The instrument’s real-time spectrum analysis capability with spectrogram function permits a detailed analysis of disturbance signals and their history. MultiView mode delivers a straightforward display of results, even for multiple operating modes.
MODEL OVERVIEW
ESW8 EMI Test Receiver 2 Hz to 8 GHz
ESW26 EMI Test Receiver 2 Hz to 26.5 GHz
ESW44 EMI Test Receiver 2 Hz to 44 GHz
Features
- Standard-compliant EMI measurements
- RF performance that meets exacting demands
- Integrated preselection filters and preamplifier
- FFT-based time domain scan for ultrafast measurements
- Realtime spectrum analysis for detailed investigation of disturbances (option)
- Convenient operation, straightforward result display
- Automated testing
- Four-channel click rate measurement
- Data protection and remote control
Specifications
Frequency range | |
R&S®ESW8 | 2 Hz to 8 GHz |
R&S®ESW26 | 2 Hz to 26.5 GHz |
R&S®ESW44 | 2 Hz to 44 GHz |
Resolution bandwidths | |
Standard filters (–3 dB) | 1 Hz to 10 MHz |
EMI filters (–6 dB) | 1 Hz, 10 Hz, 100 Hz, 200 Hz, 1 kHz, 9 kHz,
10 kHz, 100 kHz, 120 kHz, 1 MHz, 10 MHz |
Detectors (receiver mode) | max. peak, min. peak, quasi-peak, RMS,
average, average with meter time constants (CISPR-average), RMS-average (CISPR RMS) |
APD measurement function | |
Minimum amplitude probability | 10–7 |
Maximum acquisition time | 120 s |
Acquisition bandwidth (–6 dB) | 200 Hz, 9 kHz, 120 kHz, 1 MHz |
Third-order intercept (TOI) | |
R&S®ESW8, R&S®ESW26, R&S®ESW44,
RF attenuation = 0 dB, level 2 × –15 dBm, Δf > 5 × RBW, preselection off, preamplifier off |
10 MHz ≤ fin < 1 GHz, > +20 dBm, typ. 25 dBm |
1 dB compression | |
RF attenuation = 0 dB,
preselection off, preamplifier off |
fin ≤ 3 GHz, +15 dBm (nom.) |
Preselection filters | |
Receiver mode status | always on |
Analyzer mode status | on/off (selectable) |
Number of preselection filters | 21 |
Preamplifier (switchable) (1 kHz to 8 GHz) | 20 dB (nom.) |
Displayed average noise level (DANL) | |
R&S®ESW8 (receiver mode, RF attenuation = 0 dB, termination = 50 Ω, logarithmic scaling normalized to 1 Hz RBW, RBW = 1 kHz, VBW = 1 Hz, +5 °C to +40 °C, preselection on, preamplifier on) | |
Receiver mode | |
Time domain scan | |
CISPR band B, 150 kHz to 30 MHz, RBW = 9 kHz,
measurement time = 100 ms, peak detector |
110 ms (total measurement time) |
CISPR band B, 150 kHz to 30 MHz,
RBW = 9 kHz, measurement time = 1 s, quasi-peak detector and CISPR-average detector |
2 s (total measurement time) |
CISPR band C/D, 30 MHz to 1000 MHz,
RBW = 120 kHz, measurement time = 10 ms, peak detector |
620 ms (total measurement time) |
CISPR band C/D, 30 MHz to 1000 MHz,
RBW = 9 kHz, measurement time = 10 ms, peak detector |
840 ms (total measurement time) |
CISPR band C/D, 30 MHz to 1000 MHz,
RBW = 120 kHz, measurement time = 1 s, quasi-peak detector |
80 s (total measurement time) |
CISPR band C/D, 30 MHz to 1000 MHz,
RBW = 9 kHz, measurement time = 1 s, quasi-peak detector and CISPR-average detector |
67 s (total measurement time) |
Total measurement uncertainty | |
Preselection off (10 MHz < f ≤ 3.6 GHz) | ±0.27 dB |
Dimensions (nom.)
(W × H × D, including front handles and rear feet) |
462 mm × 240 mm × 504 mm
(18.15 in × 9.44 in × 19.81 in) |
Net weight, without options (nom.) | |
R&S®ESW8 | 20.6 kg (45.42 lb) |
R&S®ESW26 | 22.1 kg (48.72 lb) |
R&S®ESW44 | 25.2 kg (55.56 lb) |
Display | 30.7 cm (12.1″) WXGA color touchscreen |
Resolution | 1280 × 800 pixel (WXGA resolution) |
Data storage | |
Internal | solid state disk ≥ 32 Gbyte |
External | supports USB 2.0 compatible memory devices |
Power supply | |
AC input voltage range | 100 V to 240 V |
AC supply frequency | 50 Hz to 60 Hz/400 Hz |
Max. input current | 7.3 A (100 V) to 4.6 A (240 V) |
Power consumption | |
R&S®ESW8 without options | 150 W |
R&S®ESW8 with all options | 250 W (meas.) |
R&S®ESW26 without options | 175 W |
R&S®ESW26 with all options | 275 W (meas.) |
R&S®ESW44 without options | 200 W |
R&S®ESW44 with all options | 300 W (meas.) |