AE Techron 7548 Power Amplifier DC – 100 kHz 12kW

Description

AE Techron 7548 Power Amplifier DC – 100 kHz 12kW is a DC-enabled, high-powered unit designed to provide very low noise and fast slew rates. A single 7548 has an output capability of 100 amperes peak and 200 volts peak when driving typical MRI gradient coil loads. It can output a 40 mSec pulse with up to 105 amperes peak current into a 1- ohm load. If more current is needed, up to four amplifiers can be combined in series or parallel and operate as a single system.

The 7548 can operate in either voltage or current mode and features robust output devices and a power range of over 3300 watts RMS. It can safely drive a wide range of resistive, inductive loads.

Typical use includes as a power source for EMC testing in applications that require both continuous AC or DC signals and significant short term (burst) signals. It can be combined in a three-phase system ideal for MIL-STD- 704F (AC and 28 VDC tests).

Features

  • Over 12,000 watts peak for 40 mSec and 5,500 watts peak continuous into a 1-ohm load
  • 40 mSec pulses of up to 105 amperes peak into a 1-ohm load.
  • Frequency bandwidth of DC to 50 kHz at rated power; DC to 100 kHz at reduced power
  • Continuous system output of 800 Vp and 170 Ap maximum are possible with multiple, interconnected amplifiers
Download Data Sheet
Print
Email

Specifications

AC Specification
Frequency Response  DC – 30 kHz, +0.1, –0.5 dB
8 ohm Power Response DC-40 kHz ± 180 Vpk
DC-50 kHz ± 150 Vpk
DC-150 kHz ± 50 Vpk
DC-200 kHz ± 25 Vpk
Maximum Continuous Output Power 3300 watts RMS
Power Sinking 1.2 kVA at 120VAC
Slew Rate 41 V/μSec
Phase Response ± 5 degrees (10 Hz – 10 kHz)
Unit to Unit Phase Error +/- 0.1 degrees at 60Hz
Output Offset: 7548 Less than 5 mV, field adjustable to less than 1 mV
7548P Less than 200 μV
Output Offset Current Less than 10 mill amperes DC
DC Drift 7548 ±1.5 mV
7548P ± 400 μV (from cold to maximum operating temperature); ±200 μV (after 20 minutes of operation)
Residual Noise Unfiltered Less than 75 μV
  Filtered  (400 Hz – 30 kHz): Less than 55 μV
THD DC – 30 kHz less than 0.1%
Input Characteristics
Balanced with ground Three terminal barrier block connector 20 k ohm differential
Unbalanced BNC connector, 10 k ohm single ended
Gain Voltage Mode 20 volts/volt
  Current Mode 20 amperes/volt
Max Input Voltage ± 10 V balanced or unbalanced
Input Impedance 20 kOhm differential
Input Sensitivity 3.0V input for 3800W output into 1 ohm (adjustable)
Common Mode Rejection Range ± 11 VDC maximum
Common Mode Rejection Ratio 70 dB
Display, Control, Status, I/O
Front Panel LED Displays indicate Run, Ready, Standby, Stop, and Fault conditions in the output stage
LCD Display Lists type of fault condition and gives suggested corrective action
Soft Touch Switches for Run (Enable), Stop, Reset
User Configurable LCD display can be configured for up to four simultaneous displays reporting one, two or all four of the following: Voltage Peak, Voltage RMS, Current Peak, and Current RMS
Back Panel
Power Connection NEMA-style locking receptacle; matching AC connector also included
Signal Output 4-position terminal barrier block
Signal Input User-selectable Unbalanced BNC or Balanced Barrier Strip
Interlock Connector 25-pin D-sub connector used for amplifier control and status applications; also used in multi-amplifier applications
Communication Capabilities
Current Monitor ± 1V / 20A ±1%
Voltage Monitor ± 1V / 1V ±1%
Reporting System Fault, OverTemp, Over Voltage, Overload
Control Force to Standby; Reset after a fault
Protection
Over/Under Voltage ± 10% from specified supply voltage amplifier is forced to Standby
Over Current Breaker protection on both main power and low voltage supplies
Over Temperature Separate Output transistor, heat sink, and transformer temperature monitoring and protection
Physical Characteristics
Chassis Black powder-coat chassis with all aluminum construction; designed for stand-alone or rack-mounted operation. The amplifier occupies five EIA 19-inch-wide rack units
Weight 103 lbs. (46.7 kg)
AC Power Three-phase, 208 VAC ±10%, 47-60 Hz, 20A AC service (400 VAC ±10%, 15A version available). A toggle switch circuit breaker opens all legs of the AC mains on excess current demand.
Operating Temperature 10°C to 50°C (50°F to 122°F), Maximum Output Power de-rated above 30°C (86°F)
Humidity 70% or less, non-condensing
Cooling Forced air-cooling from front to back through removable filters via four 100 ft3/min. fans. No space is required between rack-mounted amplifiers. Air filters are removable from the rear via one fastener per side and may be eliminated if cabinet filtration is provided.
Dimensions 19 in. x 22.8 in. x 8.75 in. (48.3 cm x 57.9 cm x 22.3 cm). Unit occupies five EIA 19-inch-wide rack units.
Note: Performance levels typical up to 20 kHz frequency levels. Above 20 kHz, slew rate may affect performance, reducing maximum voltage, current and power output.