Rohde & Schwarz ZPH Cable and Antenna Analyzer 2 MHz – 4 GHz

Description

Rohde & Schwarz ZPH Cable and Antenna Analyzer 2 MHz – 4 GHz has all the essential basic measurement capabilities required for installing and maintaining antenna systems in the field. Its unique features ensure fast and efficient cable and antenna measurements and spectrum analysis. The easy-to-use analyzer features a touchscreen and large keypad designed for field use.

Features

  • Frequency range up to 3 GHz or 4 GHz, upgrade via keycode
  • One-port model features: DTF, return loss, VSWR and cable loss measurements
  • Two-port model additionally features S21 measurements, spectrum and interference analysis, AM/FM/ASK/FSK demodulation
  • Ideal for field use: up to 9-hour battery life, 2.5 kg (5.5 lb.), ruggedized housing (IP51)
Download Data Sheet
Print
Email

Specifications

Frequency range
R&S® Cable Rider ZPH (1-port model .02) 2 MHz to 3 GHz
   with R&S®ZPH-B4 option 2 MHz to 4 GHz
R&S® Cable Rider ZPH (2-port combi model .12)
   with R&S®ZPH-K1 option 5 kHz to 3 GHz
   with R&S®ZPH-B4 and R&S®ZPH-K1 options 5 kHz to 4 GHz
Frequency resolution 1 Hz
Spectrum measurement with combi model .12 only, with R&S®ZPH-K1 option
Spectral purity, SSB phase noise
  f = 500 MHz, carrier offset 30 kHz < –88 dBc (1 Hz), typ. –95 dBc (1 Hz)
  f = 500 MHz, carrier offset 100 kHz < –98 dBc (1 Hz), typ. –105 dBc (1 Hz)
  f = 500 MHz, carrier offset 1 MHz < –118 dBc (1 Hz), typ. –125 dBc (1 Hz)
Displayed average noise level (DANL) 0 dB RF attenuation, termination 50 Ω, RBW = 1 kHz, VBW = 10 Hz, sample detector, log scaling, normalized to 1 Hz
  frequency preamplifier = off
   1 MHz to 10 MHz < –130 dBm, typ. –135 dBm
   10 MHz to 1 GHz < –142 dBm, typ. –146 dBm
   1 GHz to 4 GHz < –140 dBm, typ. –144 dBm
  frequency preamplifier = on
   1 MHz to 10 MHz < –150 dBm, typ. –160 dBm
   10 MHz to 3 GHz < –158 dBm, typ. –163 dBm
   3 GHz to 4 GHz < –156 dBm, typ. –161 dBm
Maximum permissible spurious signal
  measurement = reflection (S11)/one-port cable loss/distance-to-fault analysis +17 dBm (nom.)
Data points
  selectable 101 to 2501
Measurement speed 0.3 ms/point
Result formats magnitude, VSWR, magnitude and distance-to-fault, VSWR and distance-to-fault
1-port cable loss measurement
Result format magnitude
Range
  selectable 1/2/5/10/20/50/100/120/150 dB
Distance-to-fault analysis
Result formats return loss (dB), VSWR
Fault resolution (1.5 m × 108 m × velocity factor/span)
Maximum cable length
  depending on cable loss 1500 m (nom.)
Maximum rated input levels
DC voltage 50 V
CW RF power
  model .02: port 1 (power meter input) 30 dBm
  model .12: port 1 (RF input) 20 dBm
  port 2 (reflectometer input) 23 dBm
General data
Display resolution
  WVGA 800 × 480 pixel
Battery (R&S®HA-Z306 option)
  capacity 72 Wh
  voltage 11.25 V (nom.)
  operating time with new, fully charged battery Up to 9 hrs.
Dimension
W × H × D 202 mm × 294 mm × 76 mm
(8.0 in × 11.6 in × 3 in)
Weight 2.5 kg (5.5 lb)
Applications
Watch Product Promo
Stay informed