AE Techron 2110 Gradient Amplifier

Description

AE Techron 2110 Linear Amplifier and Power Supply is a high-power, DC-enabled amplifier that offers a wide bandwidth and exceptional control of drift and distortion. The 2110 functions as a voltage or current source, making it a good choice for use in the lab or classroom. Its linear design provides a very-low noise floor and fast current rise times. Because the 2110 has no ripple noise, no synching with the console is required.

Features

  • Up to 110 Ap, 195 Vp
  • Current-mode response: DC-5 kHz (compensation dependent); Voltage-mode response: DC-20 kHz at rated power.
  • Noise Floor (when Blanking circuit is enabled): 5 µA or less
  • Current Settling Time on ramp of 0A to ±50A or ±50A to 0A: 20 µs to within 1.0A or 1%; 35 µs to within 200 mA or 0.2%
Download Data Sheet
Print
Email

Specifications

Performance
Specification typical at 25°C ambient. Unless otherwise noted; testing was done in Current mode with a load = 500 μH +100 mΩ
Peak Current Limit 112 A
Gain (adjustable) Voltage Mode 20 to 0.2 V/V µV (0.95 mV)
Current Mode 5 to 0.2 A/V
Gain Linearity

(over input signal, from 0.2V to 5V)

DC 0.0125%
AC 0.030%
Output Offset (adjustable to zero) Voltage Mode Less than ±400 μV
Current Mode ±5 mA
Input Characteristics Three-Terminal Barrier Block Connector Balanced with ground; 20 kΩ differential
BNC Connector Unbalanced; 10 kΩ single ended
Max Input Voltage ± 10 V balanced or unbalanced
Common Mode Rejection –58 dB with 5 V input
Output Impedance Current Mode (effective) 2000 Ω
Voltage Mode (typical) 3 mOhm in Series with 2.23 μH
Load Current Mode 500 μH + 100 mΩ
Adaptable Range 5 μH to 2.5 H, 0.01 Ω to 20 Ω
Current Mode Response –3 dB at 5 kHz (compensation dependent)
Current Settling Time Ramp 0 A to ±50 A or ±50 to 0 A 20 μs to within 1.0 A or 1%
35 μs to within 200 mA, 0.2%
Total Harmonic Distortion Current Mode Less than 0.1%
Load 500 μH + 100 mΩ
Noise Floor (when Blanking circuit is enabled) 5 μA or less
DC Drift Self-Heating Drift, 0 to ±60 A
5 mA/10 minutes maximum
Noise Output 10 Hz to 1 kHz 0.2 mA
1 kHz to 60 kHz 0.05 mA
Ripple Noise Output None
Slew Rate, Voltage Mode 41 V/μs
Remote Control and Monitoring

(back-panel D connector)

Current Monitor ± 1 V / 5 A ± 1%
Reporting System Fault, Over Temp, Over Voltage, Over Load
Control Force to Standby, Remove from Standby, Reset after a Fault
Amplifier Protection Over Load/Distortion (IOC) Shutdown or clipped output
Current vs Time (ODEP) Clipped output
Each heat sink temperature Shutdown 105°C
Overvoltage Shutdown 229 VAC / 440 VAC
Undervoltage Shutdown 187 VAC / 360 VAC
Status Indicators (front panel) LEDs indicate a status of Run, Ready or Standby, and Fault, Over Temp, Over Voltage, and Over Load condi­tions
Controls (front panel) AC Mains Switch and Circuit Breaker Dual-function power switch and circuit breaker; rating: 20A for 208 volts or 15A for 400 volts. Turn off and then back on to reset.
Connectors (back panel) Power Connection NEMA-style locking receptacle; matching AC connector also included
Signal Output 4-position terminal barrier block (OUT­PUT/COMMON/ SAMPLED COMMON/CHASSIS GROUND); resistor between SAMPLED COMMON and CHASSIS GROUND terminals is a 2.7-ohm, 2W, 5%, metal-oxide resistor
Signal Input User-selectable unbalanced BNC or bal­anced Barrier Strip
Interlock I/O Connection: 25-pin D connector provides for remote monitoring and control functions
Power Requirements Three-phase, 208 VAC ±10%, 47-60 Hz, 20 Amp AC ser­vice; (400 VAC ±10%, 15 Amp service model available)
Thermal Requirements Operating Temperature +10°C to +50°C (+50°F to +122°F). Maximum output power de-rated above 30° C (86°F)
Storage –30°C to +85°C (–22°F to +185°F)
Humidity 70% or less, non-condensing
Physical Characteristics Dimensions 19” L x 8.75” H x 22.8” D (48.3 cm L x 22.3 cm H x 57.9 cm D)
Cooling Forced air cooling from front to back through removable filters via four 100 CFM fans. No space is required between rack-mounted amplifiers. Air filters are removable from the rear via one fastener per side and may be eliminated if cabinet filtration is provided.
Airflow 400CFM
Weight 103 lbs (46.7 kg)
Shipping Weight 108 lbs (49.0 kg)