EM TEST CNV 504N / CNV 508N8-series Coupling/Decoupling Networks

Description

CNV 504N/508N-series Coupling/decoupling networks for signal/data lines.

Surge pulses or Ringwave pulses are applied to unshielded unsymmetrical interconnection lines (signal/data lines) by means of standalone coupling/decoupling networks. For such testing EM TEST offers a range of CNVs for either 4 or 8 signal/data lines.

According to IEC/EN 61000-4-5 and IEC/EN 61000-4-12 the pulses are coupled via different coupling elements such as capacitors or gas arrestors depending on the characteristics of the line signals.

Features

  • Coupling/decoupling networks according to IEC/EN 61000-4-5 and IEC/EN 61000-4-12
  • Coupling via gas arrestor or 0.5 µF capacitor for Surge (3.3µF capacitor for Ringwave)
  • 20mH decoupling inductor per line
  • Differential mode or Common mode coupling selectable
  • Test voltage up to 4kV, 7kV and 10kV
  • Line voltage 50V (higher voltages on request)
Download Data Sheet
Print
Email

Specifications

CNV 504N-SERIES FOR 4 UNSHIELDED UNSYMMETRICAL INTERCONNECTION LINES
CNV 504N MODELS FOR 4KV, LINE VOLTAGE MAX. 50V
CNV 504N1 4kV coupling/decoupling network max. line current 1A
CNV 504N1.1 4kV coupling/decoupling network max. line current 4A
General data Coupling/decoupling networks for Surge and Ringwave with 40ohm via 0.5μF capacitor (as per Fig. 11, IEC 61000-4-5) and arrestor (as per Fig. 12); with 3.3μF capacitor for Ringwave (as per Fig. 9, IEC 61000-4-12)
CNV 504N MODELS FOR 4KV, LINE VOLTAGE MAX. 250V
CNV 504N1.2 4kV coupling/decoupling network max. line current 1A
CNV 504N1.3 4kV coupling/decoupling network max. line current 4A
General Data Coupling/decoupling networks for Surge and Ringwave with 40ohm via 0.5μF capacitor (as per Fig. 11, IEC 61000-4-5); with 3.3μF capacitor for Ringwave (as per Fig. 9, IEC 61000-4-12)
CNV 504N MODELS FOR 7KV, LINE VOLTAGE MAX. 50V
CNV 504N2 7kV coupling/decoupling network max. line current 1A
CNV 504N2.1 7kV coupling/decoupling network max. line current 4A
General data Coupling/decoupling networks for Surge and Ringwave with 40ohm via 0.5μF capacitor (as per Fig. 11, IEC 61000-4-5) and arrestor (as per Fig. 12); with 3.3μF capacitor for Ringwave (as per Fig. 9, IEC 61000-4-12)
CNV 504N-SERIES FOR 4 UNSHIELDED UNSYMMETRICAL INTERCONNECTION LINES
CNV 504N MODELS FOR 7KV, LINE VOLTAGE MAX. 250V
CNV 504N2.2 7kV coupling/decoupling network max. line current 1A
CNV 504N2.3 7kV coupling/decoupling network max. line current 4A
General data Coupling/decoupling networks for Surge and Ringwave with 40ohm via 0.5μF capacitor (as per Fig. 11, IEC 61000-4-5); with 3.3μF capacitor for Ringwave (as per Fig. 9, IEC 61000-4-12)
CNV 504N MODELS FOR 10KV, LINE VOLTAGE MAX. 50V
CNV 504N3 10kV coupling/decoupling network max. line current 1A
CNV 504N3.1 10kV coupling/decoupling network max. line current 4A
General data Coupling/decoupling networks for Surge only with 40ohm via 0.5μF capacitor (as per Fig. 11, IEC 61000-4-5) and arrestor (as per Fig. 12) CNV 504N MODELS FOR 10KV, LINE VOLTAGE MAX. 250V
CNV 504N3.2 10kV coupling/decoupling network max. line current 1A
CNV 504N3.3 10kV coupling/decoupling network max. line current 4A
General data Coupling/decoupling networks for Surge only with 40ohm via 0.5μF capacitor (as per Fig. 11, IEC 61000-4-5)
CNV 508N-SERIES FOR 8 UNSHIELDED UNSYMMETRICAL INTERCONNECTION LINES
CNV 508N MODELS FOR 4KV, LINE VOLTAGE MAX. 50V
CNV 508N1 4kV coupling/decoupling network max. line current 1A
CNV 508N1.1 4kV coupling/decoupling network max. line current 4A
General data Coupling/decoupling networks for Surge and Ringwave with 40ohm via 0.5μF capacitor (as per Fig. 11, IEC 61000-4-5) and arrestor (as per Fig. 12); with 3.3μF capacitor for Ringwave (as per Fig. 9, IEC 61000-4-12)
CNV 508N MODELS FOR 4KV, LINE VOLTAGE MAX. 250V
CNV 508N1.2 4kV coupling/decoupling network max. line current 1A
CNV 508N1.3 4kV coupling/decoupling network max. line current 4A
General data Coupling/decoupling networks for Surge and Ringwave with 40ohm via 0.5μF capacitor (as per Fig. 11, IEC 61000-4-5); with 3.3μF capacitor for Ringwave (as per Fig. 9, IEC 61000-4-12)
CNV 508N MODELS FOR 7KV, LINE VOLTAGE MAX. 50V
CNV 508N2 7kV coupling/decoupling network max. line current 1A
CNV 508N2.1 7kV coupling/decoupling network max. line current 4A
General data Coupling/decoupling networks for Surge and Ringwave with 40ohm via 0.5μF capacitor (as per Fig. 11, IEC 61000-4-5) and arrestor (as per Fig. 12); with 3.3μF capacitor for Ringwave (as per Fig. 9, IEC 61000-4-12)
CNV 508N-SERIES FOR 8 UNSHIELDED UNSYMMETRICAL INTERCONNECTION LINES
CNV 508N MODELS FOR 7KV, LINE VOLTAGE MAX. 250V
CNV 508N2.2 7kV coupling/decoupling network max. line current 1A
CNV 508N2.3 7kV coupling/decoupling network max. line current 4A
General data Coupling/decoupling networks for Surge and Ringwave with 40ohm via 0.5μF capacitor (as per Fig. 11, IEC 61000-4-5); with 3.3μF capacitor for Ringwave (as per Fig. 9, IEC 61000-4-12)
CNV 508N MODELS FOR 10KV, LINE VOLTAGE MAX. 50V
CNV 508N3 10kV coupling/decoupling network max. line current 1A
CNV 508N3.1 10kV coupling/decoupling network max. line current 4A
General data Coupling/decoupling networks for Surge only with 40ohm via 0.5μF capacitor (as per Fig. 11, IEC 61000-4-5) and arrestor (as per Fig. 12);
CNV 508N MODELS FOR 10KV, LINE VOLTAGE MAX. 250V
CNV 508N3.2 10kV coupling/decoupling network max. line current 1A
CNV 508N3.3 10kV coupling/decoupling network max. line current 4A
General data Coupling/decoupling networks for Surge only with 40ohm via 0.5μF capacitor (as per Fig. 11, IEC 61000-4-5)
CNV 504N-SERIES FOR RAILWAY APPLICATIONS
CNV 504N7 MODELS
General Data Coupling/decoupling networks for AC/DC power ports as well as for 4 signal/data lines and I/O ports, as per EN 50121-3-3, EN 50121-4 and EN 50121-5 and IEC 61000-4-5.
CNV 504N7.2 4kV CDN for 4 signal/data lines and I/O ports, 250Vdc/1A and DC power ports, 250V (coupling only)*) and AC power ports, 250V (coupling only)*)
Coupling modes:

0.5uF/40ohm for signal/data lines, I/O ports and auxiliary AC power ports;

0.5uF/40ohm for DC power ports;

9uF/10ohm for AC/DC power ports (L/N-PE) and 18uF for AC/DC power ports (L/N)

CNV 504N7.3 4kV CDN for 4 signal/data lines and I/O ports, 250Vdc/4A and DC power ports, 250V (coupling only)*) and AC power ports, 250V (coupling only)*)

Coupling modes:

0.5uF/40ohm for signal/data lines, I/O ports and auxiliary AC power ports;

0.5uF/40ohm for DC power ports; 9uF/10ohm for AC/DC power ports (L/N-PE) and 18uF for AC/DC power ports (L/N)

*) The max. current through the CNV 504N7.x for AC or DC power port testing is limited to 32A due to the connectors used. The maximum testing current is limited by the decoupling used.