EM TEST CWS 500N2 Continuous Wave Simulator

Description

CWS 500N2 Simulator for BCI (Bulk Current Injection Testing)

EM TEST CWS 500N2 Continuous Wave Simulator is designed for testing rf conducted immunity to narrowband radiated electromagnetic energy. Apart from the injection probe and the monitoring probe everything is in the box; controller, signal generator, amplifier, directional coupler and RF power measurement of up to three signals in parallel. A built-in RF switch allows to connect and use any external amplifier to extend the system’s capabilities.

The CWS 500N2 is also designed to be used for tests with CDNs and EM clamps for tests according to EN/IEC 61000-4-6 and related standards.

 

MODEL OVERVIEW

CWS 500N2.2 Continuous Wave Simulator for BCI (Bulk Current Injection) from 9 kHz up to 1 GHz
CWS 500N2.3 Continuous Wave Simulator for BCI (Bulk current injection) from 4 kHz up to 1 GHz

Features

  • Most compact equipment
  • Supports BCI testing as per various standard requirements
  • Basic frequency range 9kHz up to 400MHz
  • Extendable frequency range up to 1GHz
  • Built-in 100W class A amplifier up to 400MHz
  • Built-in RF switch to connect external amplifier
  • Built-in directional coupler
  • Built-in 3-channel power meter up to 1GHz
Download Data Sheet
Print
Email

Specifications

BULK CURRENT INJECTION AS PER ISO 11452-4
Output level As required in ISO 11452-4, using closed loop or substitution method
BULK CURRENT INJECTION AS PER MIL 461 CS 114
Output level As required in MIL 461 CS 114, using the closed loop method
MEASUREMENTS FOR BULK CURRENT INJECTION
Directional coupler Included to measure forward power and reverse power
Forward power Internal power meter #1
Reverse power Internal power meter #2
Injected current Internal power meter #3
TEST ROUTINES FOR BULK CURRENT INJECTION
ISO 11452-4 Operation via icd.control
MIL 461 CS114 Operation via icd.control
IEC 61000-4-6
Output level 1V – 30Vrms (emf) all standard test levels are guaranteed with all coupling methods
MEASUREMENTS, IEC 61000-4-6
Cal in (BNC) Integrated power meter to record the calibration data of a coupling device
Injected current Measured by internal power meter
RF indicator LED indicating the RF output status
LCD Display of the test level and the preselected frequency value
OUTPUT
RF output N connector at the front panel
Ouptut power Built-in amplifier

50dBm (9kHz – 400MHz) at 1dB compression.

Gain amplifier > 50dB
Output impedance 50ohm
Harmonic distortion < -20dBc at max. power
Insertion loss Approx. 1dB (directional coupler + RF relay)
GENERAL DATA
Dimensions 19″/6HU
Weight approx. 31kg
Supply voltage 115V to 230V +10/-15%, 50/60Hz
Input power Max. 380W
Power factor cos (phi) = 0.96 at max. output power as per IEC 555
Fuses 2 x 6.3AT (115V) or

2 x 3.15AT (230V)

Cooling Active cooling, air ventilation
Temperature 10°C to 40°C
Rel. humidity Max. 85%, non condensing