EM TEST HSC 4-8 Coupling Network

Description

HSC 4-8 Coupling/Decoupling Assembly for Unshielded and Shielded High-Speed Communication Lines up to 1Gbit/s

EM TEST HSC 4-8 Coupling Network is used to couple Surge onto shielded and unshielded high-speed communication lines with data rates up to 1,000Mbit/s. Additionally, the HSC 4-8 can be used as a coupling/decoupling network to apply Burst- as well as Ringwave pulses to shielded and unshielded lines.

The HSC 4-8 meets the requirements according to IEC 61000-4-5.

Features

  • Coupling to unshielded and shielded lines with up to 4 pairs
  • Data transfer up to 1,000 Mbit/s
  • Surge test voltage up to 3 kV (1.2/50 us)
  • Burst test voltage up to 4 kV (5/50 ns)
  • Ringwave test voltage up to 4 kV (0.5 us/100 kHz)
  • Residual voltage max. 50 V at 3 kV Surge
  • Compatible to PoE and PoE+ requirements
  • DUT/AE connection via RJ45 connectors
Download Data Sheet
Print
Email

Specifications

SURGE TEST MODE
Coupling mode shielded and unshielded cable with up to 4 pairs
Test voltage Max. 3 kV* (1.2/50us)

(* only with connected RJ45 connector; if left open the max. test voltage is limited to 1.5 kV)

Residual voltage Max. 50V @3 kV Surge, line – PE
RINGWAVE TEST MODE
Coupling mode shielded and unshielded cable with up to 4 pairs
Test voltage Max. 4 kV* (0.5 us/100 kHz)

(* only with connected RJ45 connector; if left open the max. test voltage is limited to 1.5 kV)

Residual voltage

line – PE

Max. 50V @2 kV Ringwave

Max. 50V @4 kV Ringwave

BURST TEST MODE
Coupling mode shielded cable with up to 4 pairs
Test voltage Max. 4 kV* (5/50 ns)

(* only with connected RJ45 connector; if left open the max. test voltage is limited to 1.5 kV)

Residual voltage

line – PE

Max. 40 V @2 kV Burst

Max. 60 V @4 kV Burst

TELECOM LINE SPECIFICATIONS
Input/output RJ45 female connectors for telecom lines
Terminal layout Pair 1: pins 1/2

Pair 2: pins 3/6

Pair 3: pins 4/5

Pair 4: pins 7/8

Data rate up to 1,000 MBit/s
Protection ± 60 V between two pairs
Operating voltage max. 57 VDC
Operating current max. 1 A
INPUTS
Surge/Ringwave shield SHV connector
Surge unshielded SHV connector
Ringwave unshielded SHV connector
Burst SHV connector
GENERAL DATA
Dimensions (LxWxH) 270 mm x 110 mm x 140 mm
Weight 6.5 kg
Temperature 5°C – 40°C (operation)
Rel. humidity 10 % – 90 %, non-condensing
Stay informed