EM TEST Transient Emission Set
Description
EM TEST Transient Emission Set consisting of the BS 200N100 electronic switch, the artificial network AN 200N100 and the BSM 200N40 mechanical switch is an easy-to-use, economic and compact solution, fully compliant to ISO 7637-2.
Small size of the equipment and short interconnections allow to meet the distances specified by the standard. An optional resistor box RS-Box with shunt resistor is available for transient emission measurements as per ISO 7637-2:2004 and ISO 7637-2:2011.
The RS-Box offers the required 40ohm shunt resistor and other demanding shunt resistors values of e.g. 10ohm, 20ohm and 120ohm.
Features
- BS 200N100 – Electronic switch, 60V DC/100A:
- – Volt. Drop <1.2V@100A, <0.2V@25A
- – Peak voltage max. 1,000V
- – Reverse-polarity/short-circuit protected
- BSM 200N40 – Mechanical switch, 12/24V DC/40A
- AN 200N100 – ISO 7637-2, CISPR 25, CISPR 16-1-2
- – Frequency range 100kHz – 125MHz
- – 1,000V DC, 250V AC (up to 1kHz)
- – Current max. 100A AC/DC cont.
- – Insertion loss < 3dB
Download Data Sheet
Print
Email
Specifications
BS 200N100 – ELECTRONIC SWITCH | |
SPECIFICATION | |
Operation voltage | Max. 60V DC |
Operation current | Max. 100A continuous |
Peak voltage | Max. 1,000V |
Inrush current | Max. 400A for 200ms |
Voltage drop | < 1.2V at 100A
< 0.2V at 25A |
Overvoltage protection | By varistors |
Overload protection | Short-circuit protected
Reverse-polarity protected |
AN 200N100 – ARTIFICIAL NETWORK | |
TECHNICAL DATA | |
as per | ISO 7637-2, CISPR 25, ISO 11452-4 and CISPR 16-1-2, switchable |
Frequency range | 0.1 to 125MHz |
Operation voltage | 1,000V DC/250V AC up to 1kHz |
Operation current | Max. 100A AC/DC continuous |
Inrush current | Max. 400A for 200ms |
Impedance | 5uH // 50ohm for details see datasheet |
Insertion loss | less than 3dB DUT to receiver output |
Inductance | 5uH +/-10% air-core coil |
Coupling capacitor | 0.1uF |
BSM 200N40 – MECHANICAL SWITCH | |
SPECIFICATIONS | |
Operation voltage | DUT supply 12V/24V |
Operation current | Max. 40A DC continuous, resistive load |
Maximum current Imax | 40A @13.5V
20A @27.0V |
Contact | high purity silver contacts, no suppression across relay contact, insulated from the coil circuit |