EM TEST VCS 500N7T Telecom Surge Generator

Description

VCS 500N7T – Compact surge / Telecom surge generator with integrated CDN up to 7kV

EM TEST VCS 500N7T Telecom Surge Generator unifies the test capabilities for Combination wave surge and telecom surge testing in one unit up to 7kV as per IEC/EN 61000-4-5 and IEC/EN 61000-4-9. It offers built-in coupling/decoupling networks for single phase AC power port and telecom port testing.

Surge pulses occur due to direct or indirect lightning strokes to an external (outdoor) circuit. This leads to currents or electromagnetic fields causing high voltage or current transients. Due to the characteristic of the phenomenon nearly every electrical and electronically a device may suffer from such lightning events which justifies the necessity of surge tests being widely performed.

For combination wave surge tests on high-current mains supply lines its capability can be extended by an external CDN to achieve nominal currents of 100 A and more per phase.

 

MODEL OVERVIEW

VCS 500N10T Combined combination wave and Telecom surge generator up to 10KV

Features

  • Surge voltage up to 7 kV
  • Surge current up to 3.5 kA
  • Telecom surge voltage up to 7 kV
  • Telecom surge current up to 465 A
  • Voltage/current monitors
  • Built-in 1ph CDN 16 A
  • Interlock
  • Warning lamp control
  • Manual operation
  • USB and GPIB interface
Download Data Sheet
Print
Email

Specifications

SURGE GENERATOR
AC POWER PORT TESTING, PULSE 1.2/50US – 8/20US AS PER IEC 61000-4-5
Voltage (o.c.) 250V – 7,000V ±10%
Rise time 1.2us ± 30%
Pulse duration 50us ± 20%
Current (s.c.) 125A – 3,500A
Rise time 8us ± 20%
Pulse duration 20us ± 20%
Polarity Positive, negative or alternating
Counter 1 – 30,000 or endless
TELECOM PORT TESTING, PULSE 10/700US AS PER IEC 61000-4-5
Voltage (o.c.) 250V – 7,000V ±10%
Rise time 10us ± 30%
Pulse duration 700us ± 20%
Current (s.c.) 6.25 – 175A
Rise time 5us ± 20%
Pulse duration 320us ± 20%
Energy storage capacitor 20uF
Polarity Positive, negative or alternating
Counter 1 – 30,000 or endless
GENRAL DATA
INTERFACE
Serial interface USB
Parallel interface IEEE 488, addresses 1 – 30
CN interface To control external coupling matrix
DIMENSIONS
Dimensions 19″/6HU
Weight approx. 34kg
Supply voltage 115/230V _10/-15%
Fuses 2×2 AT (230V) or 2×4 AT (115V)
Stay informed